摘要
为降低火电厂厂用电率,火电厂都已大范围采用高低压变频调节技术节能降耗。针对使用IGBT作为功率器件的变频器自身的特点进行分析,对其在现场应用可能出现的一些实际问题提出解决办法并简要论述冲灰泵电机变频调速改造方案,总结一台变频器带两台公用负载的改造经验。
Power plants employ the high-low voltage variable frequency regulation in wide range in order to reduce, power consumption rate. Considering variable frequency regulation's characteristics, with IGBT as its power device, the paper proposes solutions for application problems. Also, reform scheme is discussed and experience of one inverter driving two public loads is summarized.
出处
《江西电力》
2009年第3期6-8,共3页
Jiangxi Electric Power
关键词
变频
现场应用
冲灰泵
改造
variable frequency
application on spot
ash flushing pipe
reform