期刊文献+

考虑风速特性的动态电压崩溃指标 被引量:3

Dynamic voltage collapse index with wind speed considering
下载PDF
导出
摘要 基于四分法划分的风速模型和简化风力发电系统传输线路模型,考虑3阶双馈异步风力发电机的转差率和风电机注入系统功率的随机性,推导出电压崩溃指标.根据指标测量值与临界值之间的距离判定系统接近电压崩溃的程度;投入SVC补偿可提高该指标,即提高系统电压崩溃的预防能力.最后以配电网系统中接入单台风力发电机为例,基于MATLAB的Simulink对风速、滑差和动态电压崩溃指标进行仿真,仿真结果验证了该指标的有效性和实用性. Based on the quarter wind speed model and the simplified wind power transmission line model, the dynamic voltage collapse index is deduced with the slip ratio of 3-order doubly-fed induction wind turbines and the random power of wind turbines injecting into power systems considered in this paper. The degree of power system close to voltage collapse is calculated with the magnitude between the local measuring index value and the critical value. After SVC connecting, the wind power system index value and the voltage stability can increase. At last, a distribution network system with a single wind generator is simulated using the Simulink model of MATLAB. The wind speed, slip ratio and dynamic voltage collapse index are calculated. Simulation results show that the index is with validity and practicability.
出处 《电力科学与技术学报》 CAS 2009年第2期41-46,共6页 Journal of Electric Power Science And Technology
基金 湖南省教育厅优秀青年基金(06B007) 电力系统及发电设备安全与仿真控制国家重点实验室开放基金(GZH(2008)07)
关键词 风力发电系统 动态电压崩溃指标 相量测量单元 四分法风速 wind power system dynamic voltage collapse index phasor measurement unit the quarter wind model
  • 相关文献

参考文献16

二级参考文献165

共引文献1410

同被引文献38

  • 1李东东,陈陈.风力发电系统动态仿真的风速模型[J].中国电机工程学报,2005,25(21):41-44. 被引量:109
  • 2陈海焱,段献忠,陈金富.分布式发电对配网静态电压稳定性的影响[J].电网技术,2006,30(19):27-30. 被引量:133
  • 3曹娜,赵海翔,任普春,戴慧珠.风电场动态分析中风速模型的建立及应用[J].中国电机工程学报,2007,27(36):68-72. 被引量:64
  • 4Miguel García-Gracia,M. Paz Comech,Jesús Sallán,Andrés Llombart.Modelling wind farms for grid disturbance studies[J].Renewable Energy.2007(9)
  • 5E. Welfonder,R. Neifer,M. Spanner.Development and experimental identification of dynamic models for wind turbines[J].Control Engineering Practice.1997(1)
  • 6Bu S Q,Du W J? Wang H F,et al. Power angle controlof grid-connected doubly fed induction generator windturbines for fault ride-through [J], Renewable PowerGeneration, IET, 2013,7(1):18-27.
  • 7Vittal E,O'Malley M, Keane A. Rotor angle stabilitywith high penetrations of wind generation [J], IEEETransactions on Power Systems, 2012? 27 ( 1 ) : 353-362.
  • 8Muljadi E,Butterfield C P,Parsons B, et al. Effect ofweak grid[J]. IEEE Transactions on Energy Conver-sion, 2007, 22(1):29-36.
  • 9Nunes M V A, Peas Lopes J A, Zurn H H, et al. In-fluence of the variable-speed wind generators in transi-ent stability margin of the conventional generators in-tegrated in electrical grids [J]. IEEE Transactions onEnergy Conversion, 2004,19(4) :692-701.
  • 10namic modeling of doubly fed induction generator windturbines[J]. IEEE Transactions on Power Systems,2003, 18(2):803-809.

引证文献3

二级引证文献27

相关作者