导出
摘要 针对广州珠江新城某超高层建筑的内循环式双层幕墙结构,采用门窗幕墙热工模拟计算系列软件,分别对封闭及通风状态下的内、外层传热系数、遮阳系数以及可见光透射比等参数进行模拟计算,同时采用CFD技术对典型工况下内置遮阳百叶的遮阳效果进行模拟计算,将分析研究成果直接用于指导该项目双层幕墙的热工设计及建筑节能设计,对类似工程提供参考。 Thermal performance simulated investigation was carried out for a supper tall-building with internal circulation curtain wall at Zhu Jiang New City of Guangzhou. Simulated computation was carried out for heat transmission coefficient,shading coefficient and trans- mission adopted the software of thermal simulating for curtain wall and window,ere,which included close and open status,respectively. At the meantime, the shading effective of interior shading shutter on typical work conditions was simulated using CFD simulation technique. Through comprehensive analysis,the research results of this paper instruct the thermal design of double curtain wall of this tall building directly,and have a lot of benefits for other practice projects.
出处 《广东土木与建筑》 2009年第4期48-50,53,共4页 Guangdong Architecture Civil Engineering
关键词 双层幕墙 内循环 遮阳百叶 CFD 热工性能 double curtain wall internal circulation Shading shutter computation Fluid Dynamics thermal performance
  • 相关文献

参考文献6

二级参考文献18

  • 1李鹏,曹立勇,楼文娟,陈勇.双幕墙高层办公楼通风效果风洞试验研究[J].暖通空调,2004,34(11):15-18. 被引量:4
  • 2江宏俊.流体力学[M].北京:高等教育出版社,1988.230-234.
  • 3Guohui Gan. Thermal transmittance of multiple glazing:computational fluid dynamics prediction[J]. Applied Thermal Engineering 2001, (21) 1583-1592.
  • 4M.A. Bernier, B. Bourret, Effects of glass plate curvature on the U-factor of sealed insulated glazing units[J]. ASHRAE Transactions 1997, 103 (1):270-277.
  • 5M.G. Hutchins, W J Platzer. Thermal performance of advanced g]azing materials[J].Renewable Energy 1996,8(1): 540-545.
  • 6J A Clarke, M Janak, P . Puyssevelt, Assessing the overall performance of advanced glazing systems[J].Solar Energy 1998, 63(4) :231-241.
  • 7叶歆.建筑热环境[M].北京:清华大学出版社,1995..
  • 8Wojtek Stec, Dolf van Passen. Defining the performance of the double skin facade with the use of the simulation model. Building Simulation, 2003.
  • 9Howell S A, Potts I. On the natural displacement ventilation flow through a full scale enclosure, drivenby a source of buoyancy at floor. Building Simulation,2001.
  • 10Raithby G D, Chu E H. A finite-volume method for predicting a radiant heat transfer in enclosures with participating media. ASME J Heat Transfer, 1990,112:415 - 423.