期刊文献+

点接触锁定加压接骨板固定骨质疏松粉碎性桡骨骨折的生物力学特性 被引量:3

Biomechanical research on new type point contact locking compression plate with osteoporotic comminuted radial fracture model
下载PDF
导出
摘要 目的对比研究新型点接触锁定加压接骨板(point contact locking compression plate,PC-LCP)和动力加压接骨板(DCP)固定老年骨质疏松粉碎性桡骨骨折的生物力学特性。方法选取12对老年骨质疏松性尸体桡骨制成横断骨折,骨折间隙为1cm,模拟粉碎性骨折模型。每对随机选取,其中一根用PC-LCP固定,另一根用DCP固定。进行前后四点弯曲、内外四点弯曲及扭转实验,得到相应的弯曲刚度和扭转刚度。结果PC-LCP固定骨质疏松粉碎性桡骨骨折后的弯曲刚度及扭转刚度均高于DCP,但两者没有统计学差异(P>0.05)。结论新型接骨板PC-LCP固定骨质疏松粉碎性桡骨骨折的生物力学特性优于DCP。 Objective Biomechanical comparison between a new type of point contact locking compression plate and dynamical compression plate was made with an osteoporotic comminuted radial fracture model. Method Twelve pairs of aged osteoporotic cadaveric radial transverse fracture with lcm clearance were created to simulate comminuted fracture and each pair was fixed with PC-LCP,DCP, respectively. Then the anteroposterior four point bending,mediolateral four point bending and torsion tests was conducted to determine the bending and torsion compress stiffness of the PC-LCP and DCP. Result Both the bending and torsion stiffness of PC-LCP are higher than that of DCP, but there are no significant differences (P 〉0.05). Condusions The new PC-LCP has a tendencyto osteoporotic comminuted radial fracture.
出处 《医用生物力学》 EI CAS CSCD 2009年第3期200-203,共4页 Journal of Medical Biomechanics
基金 重庆市科技攻关重大项目(CSTC,2006AA5014-1)
关键词 接骨板 点接触 锁定加压 生物力学 骨折 Bone plate Point contact Locking have higher bending and torsion stiffness when used to fixthe compression Biomechanics Frature
  • 相关文献

参考文献4

二级参考文献9

共引文献56

同被引文献37

  • 1王超,张春秋,董心,刘海英.骨功能适应性数值模拟的若干进展[J].医用生物力学,2008,23(5):399-404. 被引量:4
  • 2照那木拉.蒙医传统整骨术的整骨疗法系统模型及其数理表述方法[J].中国骨伤,2004,17(10):627-629. 被引量:4
  • 3照那木拉,李根全,苏和平,包常明,吉日嘎拉,王朝鲁.中国传统整骨理念、手法的生物力学机制及其数理表述(英文)[J].中国临床康复,2005,9(14):244-247. 被引量:12
  • 4Perren SM. Backgrounds of the technology of internal fixators [ J ].Injury, 2003,34 ( S2 ) : 1 - 3.
  • 5Chapman JR, Harrington RM, Lee KM. Factors affecting the pullout strength of cancellous bone screws [ J 1. J Biomech Eng,1996,118(3) :391 -398.
  • 6Egol KA, Kubiak EN, Fulkerson E, et al. Biomechanics of locked plates and screws[ J]. J Orthop Trauma,2004, 18 (8) :488 -493.
  • 7Ring D, Kloen P, Kadzielski J, et al. Locking compression plates for osteoporotic nonunions of the diaphyseal humerus [ J ].Clin Orthop Relat Res,2004,425 (1):50- 54.
  • 8Ring D, Percy BH, Jupiter JB. The functional outcome of operative treatment of ununited fractures of the humeral diaphysis in older patients [ J ]. J Bone Joint Surg ( Am), 1999,81 (2) : 177 - 190.
  • 9Zhao YF, Li QH, Gu ZC, et al. The biomeehanies of point contact dynamic compression plate and its effects on bone perfusion [ J ]. Chin J Traumatol, 2006,9 (3) : 161 - 167.
  • 10O'Beirne J, O Connell R J, White JM, et al. Fractures of the femur treated by femoral plating using the anterolateral approach [J]. Injury, 1986,17 (6): 387 - 390.

引证文献3

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部