摘要
目的:了解惠州市军团菌的污染现状及人群军团菌的感染程度,为制定预防和控制军团菌感染策略提供依据。方法:采用分离鉴定与ELISA方法,对惠州市186份集中空调冷却塔水进行军团菌分离鉴定,对215例暴露人群及152例对照人群进行军团菌抗体IgG检测。结果:本次调查集中空调嗜肺军团菌检出率为51.3%,共检出62株嗜肺军团菌,其中,LP1型37株、LP2~LP14型25株;215份暴露人群中检出军团菌抗体阳性29份,阳性率13.4%,152份对照人群中检出军团菌抗体阳性7份,阳性率4.6%。结论:惠州市集中空调冷却塔水中军团菌污染现状较为严重,已对暴露人群的健康造成潜在威胁,对这一潜在传染来源应采取立体、有效防范措施。
Objective: To investigate the status of the Legionella contamination and infection in crowd in Huizhou City,in order to constitute the prevention and control strategy of Legionella infection.Methods: 186 Cooling tower water samples from central air conditioning system in Huizhou City were cultured and then Legionella was isolated and identified; The antibodies IgG against Legionena of 215 dangerous group and 152 control were detected by Enzyme - linked Immunosorhent Assay( ELISA). Results: The detection rate of Legionella pneumophilia in this survey of central air conditioning system is 51.3 % ,62 strains of Legionella pneumophilia were isolated, among them 37 strains were serovar LP1, and 25 strains were serovar LP2 - LP14 ; There were 29 cases of anti - Legionella positive in the 215 dangerous group, with the positive rate of 13.4%, and there were 7 cases of anti - Legionella positive in the 152 control, with the positive rate of 4.6% ; Conclusion: The water in cooling tower of central air conditioning system in Huizhou city has been contaminated seriously with Legionella,and it has already being a latent threat to the health of dangerous group, thus spatial and effective preventive measures to this potential source of infection should be taken as soon as possible.
出处
《中国民康医学》
2009年第14期1627-1627,1659,1663,共3页
Medical Journal of Chinese People’s Health
关键词
军团菌
抗体
集中空调
Legionella
Antibodies
Central air conditioning