摘要
通过投运后锅炉燃烧调整试验,证明了燃烧器顶部布置反向OFA是一种减少四角切圆燃烧残余旋转引起的烟温偏差的有效方法。
Through the boiler combustion experiment, it was proved as an effective method to reduce the flue gas temperature deviation by the arrangement of reversed OFA on the top of burner.
出处
《电站系统工程》
北大核心
2009年第4期7-8,共2页
Power System Engineering
关键词
烟温偏差
四角切圆
OFA
对流换热
flue gas temperature deviation
tangentially fired
OFA
convective heat exchange