摘要
用瞬态热流法测定玉米的热导率。玉米的含水率为9.25%~17.14%,温度为-32.3~17.2℃。结果表明:用0.40A电流测得的热导率与用0.44和0.36A测得的热导率没有明显差别;在加热时间分别为8,9和10min测得的热导率之间也没有明显差别。热导率与含水率和温度呈现良好的线性关系。
The thermal conductivity of corn is measured by the transient heat flow method.Before measurement, the moisture content of the corn is in the range of 9. 25% to 17. 14%,and its temperature is of -32. 3℃ to 17. 2℃. The results show that the thermal conductivity is no obvious difference when current is 0. 40 A compared with those tested under 0. 44 A and 0. 36 A. The thermal conductivity is also no obvious difference when the heating periods are 8, 9 and 10 min, respectively. It has been found that the thermal conductivity is a linear function of the mositure content and temperature.
出处
《中国农业大学学报》
CAS
CSCD
北大核心
1998年第4期29-32,共4页
Journal of China Agricultural University
关键词
玉米
热导率
瞬态热流法
贮藏
corn
thermal conductivity
transient heat flow method