期刊文献+

^(10)B靶转换法测量金属钚质量的MC模拟

Monte Carlo simulation for measuring the mass of metal plutonium with ^(10)B converting target
下载PDF
导出
摘要 为验证硼转换法测量金属钚质量的可行性,模拟计算并设计了一个10B转换靶。该方法是军控核查中测量金属钚质量的新方法,利用10B靶将金属钚自发裂变中子转化为478keVγ射线,由γ射线的计数信息反推算金属钚质量。研究重点是通过蒙特卡罗程序模拟中子-光子转化输运过程,调整10B靶体的各项参数(成分、厚度、位置、形状等)获得尽可能高的转换效率。优化模型的模拟计算结果使478keVγ射线产额在设计条件下超过10-5,满足公斤级金属钚的探测要求,为方案实施提供理论依据。 A new method for arms control inspections of metal plutonium has been developed. It measures the 478 keV T ray from ^10B(n, α) ^7Li reaction by neutrons generated in spontaneous fission of ^240Pu in metal plutonium being inspected. In this work, simulations were performed for the converting and transporting process of neutron-photon, and adjusting parameters of the ^10B target, including the ^10B content of the target, thickness of the target, and the geometry parameters, in an attempt to optimize the converting efficiency. The results show that the method could be achieved detection efficiency of gamma yield of 〉10^-5 per neutron, which allows the detection of kilogram of weapon-grade metal plutonium.
出处 《核技术》 CAS CSCD 北大核心 2009年第7期525-528,共4页 Nuclear Techniques
关键词 军控核查 10B靶 射线产额 金属钚质量 Arms control, ^10B target, Gamma production rate, Mass of metal plutonium
  • 相关文献

参考文献5

  • 1Arms Control and Nonproliferation Technologies.Technology R&D for Arms Control,2001
  • 2刘素萍,龚建,郝樊华,伍怀龙,胡广春,向永春,迮仁德,章建华.密封容器中钚材料同位素丰度和年龄的测量[J].核技术,2006,29(3):229-233. 被引量:2
  • 3杜祥琬.核军备控制的科学技术基础.北京:国防工业出版社,1996.363-367.
  • 4Doug Reilly,Norbert Ensslin.Passive nondestructive assay of nuclear materials,LANL 1991.384-386
  • 5X-5 Monte Carlo Team,Diagnostics Applications Group.MCNP-A General Monte Carlo N-Particle Transport Code Version 5,Volume Ⅱ:MCNP User's Guide.Los Alamos National Laboratory.2003.1-194

二级参考文献5

  • 1Comley C,Comley M,Eggins P,et al.Confidence,security and verification:The challenge of global nuclear weapons arms control.AWE/TR/2000/001.
  • 2Tian Dongfeng,Xie Dong.Nuclear Instruments and Methods in Physics Research,Section A,2000,449:500-504.
  • 3Sampson T E.Plutonium istopic composition by gamma-ray spectroscopy:A review.LA-10750-MS.
  • 4宋明胜.测量不确定度评定与数据处理.北京:中国计量出版社,2000.233-234.
  • 5龚建,郝樊华,熊宗华.相对效率法同位素丰度分析的研究[J].核电子学与探测技术,2001,21(4):287-289. 被引量:9