期刊文献+

原子吸收法测定水样中铅含量的测量不确定度评定 被引量:2

Evaluation of Uncertainty Measurement of the Lead Content in Water Samples by AAS
下载PDF
导出
摘要 根据GB/T7475-1987,使用原子吸收光度法测定水质样品中铅的含量,按照JJF1059-1999《测量不确定度评定与表示》的要求对测定结果进行不确定度评定。分析测定过程中不确定度来源,计算各不确定度分量,求出合成不确定度和扩展不确定度,给出测定结果报告。当样品铅含量为1.31 mg/L时,测量结果的扩展不确定度为0.05 mg/L,k=2。 According to GB/T7475-1987,the lead content in water samples was determined by atomic absorption spectrophotometry, and the uncertainty of the determination result was evaluated on the requirement of ((Evaluation and Expression of Uncertainty in Measurement)) (JJF1059-1999). Analyzing the sources of uncertainty in the entire course of the determination and calculating each component of uncertainty, the combined uncertainty and expanded uncertainty were obtained, and the determination result of the copper content was also given. While the lead content in detected samples is 1.31 mg/L, the extend uncertainty of the determination result was 0.05 mg/L, k=2.
出处 《现代科学仪器》 2009年第3期80-82,共3页 Modern Scientific Instruments
关键词 原子吸收法 水质样品 不确定度 Atomic absorption spectrometry Water samples Lead Uncertainty
  • 相关文献

参考文献4

  • 1国家环保总局.水和废水监测分析方法(第4版)[M].北京:中国环境科学出版社,2002.670-671.
  • 2JJF1059-1999.测量不确定度评定与表示[S].[S].,..
  • 3中国实验室国家认可委员会,化学分析中不确定度评定的评估指南[M],北京:中国计量出版社,2002
  • 4谢玉珊,罗惠明,刘江晖,姚红,谢湘娜.石墨炉原子吸收法测定奶粉中铜质量分数的不确定度评定[J].现代测量与实验室管理,2008,16(2):21-23. 被引量:2

二级参考文献1

  • 1[3]杨惠芬等.食品卫生理化检验手册(第一版).北京:中国标准出版社,1998

共引文献850

同被引文献1171

引证文献2

二级引证文献20