期刊文献+

呼吸控制技术在肺部肿瘤精确放射治疗中的应用 被引量:4

The Study on Breathing-control Technique Used in Lung Tumor Accurate Radiation Therapy
下载PDF
导出
摘要 为了克服呼吸运动对肿瘤精确照射造成的不利影响,在放疗过程中运用各种呼吸控制技术限制肿瘤的呼吸运动范围,尽量减少肿瘤在每一个呼吸周期内的最大位移量,实践证明这些方法都能够有效地提高肿瘤的治疗增益比。我们比较了已有的多种呼吸控制方法的优缺点,并重点介绍了肿瘤呼吸运动位移误差补偿技术的具体实现过程,展望了呼吸运动控制技术的前景。 To overcome the adverse effects on precise tumor irradiation caused by respiratory movement, During the course of radiotherapy,a variety of breathing - control techniques is utilized to limit the range of tumors' respiratory movement, reduce the maximum displacement of tumor in each breathing period as far as possible, practice has proved that these several methods can improve the treatment gain of the tumors. The advantage and disadvantage during these several existed methods of respiratory control on the base of positively tracking the latest related articles at home and abroad are compared and how to carry out the process of respiratory tumor movement displacement error compensation technology is introduced.
作者 伍锐 陈超敏
出处 《生物医学工程研究》 2009年第2期159-162,共4页 Journal Of Biomedical Engineering Research
关键词 呼吸运动 精确照射 治疗增益比 呼吸控制 位移误差补偿 Breathing movement Precise radiotherapy Therapeutic gain ratio Respiratory control Displacement error compensation
  • 相关文献

参考文献15

  • 1胡逸明,戴建荣,张红志,等.肿瘤放射物理学[M].原子能出版社,1999:538.
  • 2黄伟,李宝生,于金明.精确放疗中呼吸运动对肺部肿瘤靶区的影响与控制[J].国际肿瘤学杂志,2005,32(1):53-56. 被引量:25
  • 3Herfarth KK,Debus J,Lohr F,et al.Extracranial stereotactic radiation therapy:set-up accuracy of patients treated for liver metastases[J].Int J Radiat Oncol Biol Phys,2000,46(2):329-335.
  • 4Negoro Y,Nagata Y,Aoki T,et al.The effectiveness of an immobilization device in conformal radiotherapy for lung tumor:reduction of respiratory tumor movement and evaluation of the daily setup accuracy[J].Int J Radiat Oncol Biol Phys,2001,50(4):889-898.
  • 5Rosenzweig KE,Hanley J,Mah D,et al.The deep inspiration Breath-hold technique in the treatment of inoperable non-small-cell lung cancer[J].Int J Radiat Oncol Biol Phys,2000,48 (1):81-87.
  • 6Hanley J,Debois MM,Mah D,et al.Deep inspiration breath-hold technique for lung tumors:the potential value of target immobilization and reduced lung density in dose escalation[J].Int J Radiat Oncol Biol Phys,1999,45(3):603-611.
  • 7Wong JW,Sharpe MB,Jaffray DA,et al.The use of active breathing control (ABC) to reduce margin for breathing motion[J].Int J Radiat Oncol Biol Phys,1999,44(4):911-919.
  • 8Miohara S,Kanai T,Endo M,et al.Respiratory gated irradiation system for heavy-ion radiotherapy[J].Int J Radiat Oncol Biol Phys,2000,47(4):1097-1103.
  • 9Lagerwaard FJ,Van Sornsen de Koste JR,Nijssen Visser MR,et al.Multiple "slow"CT scans for incorporating lung tumor mobility in radiotherapy planning[J].Int J Radiat Oncol Biol Phys,2001,51(4):932-937.
  • 10伊志强.机电一体化设计[M].合肥:机械工业出版社,2007.

二级参考文献47

  • 1梁亚玲,刘静,杜明辉.H.264中块运动估计及其发展趋势[J].电视技术,2005,29(z1):40-43. 被引量:4
  • 2陈超敏,周凌宏,吕庆文.我国立体定向放射治疗设备的现状与发展[J].医疗卫生装备,2003,24(S1):124-125. 被引量:15
  • 3[1]Stevens C W, Munden R F, Forster K W, et al. Respiratory-driven lung tumor motion is independent of tumor size, tumor location, and pulmonary function [J]. Int J Radiat Oncol Biol Phys, 2001, 51: 62-68.
  • 4[2]Wong J W, Sharpe M B, Jaffray D A, et al. The use of active breathing control (ABC) to reduce margin for breathing motion [J]. Int J Radiat Oncol Biol Phys, 1999, 44:91-1919.
  • 5[4]Shirato H, Shimizu S, Kitamura K, et al. Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor [J]. Int J Radiat Oncol Biol Phys, 2000, 48: 435-442.
  • 6[5]Murphy M J, Cox R S. The accuracy of does localization for an image guided frameless radiosurgery [J]. Med Phys, 1996,23:2043-2049.
  • 7[6]Ohara K, Okumura T, Akisada M, et al. Irradiation synchronized with respiration gate[J]. Int J Radiat Oncol Biol Phys, 1989,17: 853-857.
  • 8[7]Shirato H, Shimizu S, Kunieda T, et al. Physical aspects of a real-time tumor tracking system for gated radiotherapy [J]. Int J Radiat Oncol Biol Phys, 2000, 48: 1187-1195.
  • 9[8]Kubo H D, Hill B C. Respiration gated radiotherapy treatment: a technical study [J]. Phys Med Biol, 1996, 41:83-91.
  • 10[9]Rajapakshe R, Shalev S. Output stability of a linear accelerator during the first three seconds [J]. Med Phys, 1996, 23:51-7519.

共引文献42

同被引文献43

引证文献4

二级引证文献18

相关作者