摘要
采用光电子能谱(XPS)研究钢筋钝化膜的组成与结构,以及氯离子对钝化膜的影响。结果表明,在本实验条件下钢筋钝化膜为双层结构,外层以γ-FeOOH为主,内层主要为FeO;氯离子对胶的破坏过程可能是先在钝化膜表面吸附,然后穿透到膜中,在铁/氧化物界面即膜的内层形成FeCl_2,而使钝化膜局部溶解;复合缓蚀剂的加入使钢筋钝化膜表面γ-FeOOH的含量增大,膜中夹杂一定深度的有机铵盐,硅酸盐只在表面沉积。
The composition and structure of rebar passive film as well as the effect of composite inhibitors and chloride ions on the film were studied by X-ray photoelectron spectroscopy. It was found that γ- FeOOH was the major oxide in the outer layer and the inner layer only contained FeO. The machanism of pitting corrosion induced by Cl- might be as follows. First, chloride ions adsorbed on rebar passive film, then they penetrated into the film through defects and accumulated in the inner layer of the film. Cl- and Fe2+ might form into FeCl2, so the passive film dissolved from its inner layer locally. After adding composite inhibitors, γ-FeOOH content in the outer layer increased and organic ammonium incorporated in the film to certain depth, and silicate only deposited on the surface of the film.
出处
《中国腐蚀与防护学报》
CAS
CSCD
1998年第2期107-112,共6页
Journal of Chinese Society For Corrosion and Protection
基金
厦门大学国家表面物理化学重点实验室资助项目
江苏省自然科学基金资助项目
国家杰出青年科学基金资助项目
关键词
X射线
光电子能谱
钢筋
缓蚀剂
氯离子
X-ray photoelectron spectroscopy(XPS), Rebar passive film, Composite inhibitor, Chloride ion