摘要
据有限空间紊流射流理论,提出了先假设空调房间只设置一个大风口,确定送风速度和送风射流自由度,然后确定实际所需送风口个数和送风口直径的计算方法.图2,表1,参3.
According to thd theory of limited space turbulent jet flow,we advance a new method.First supposing one tuyere is only set up in the air conditioning room,the velocity and freedom of jet flow are calculated out,then decide the factual number and diameter of turyere are decided.2figs.,1tab.,2refs.
出处
《湘潭矿业学院学报》
1998年第2期45-50,共6页
Journal of Xiangtan Mining Institute
关键词
侧送风
大风口
送风速度
气流分布
优化计算
lateral supply,large tuyere,velocity of air supply,degree of freedom