期刊文献+

感应电动机直接转矩控制系统的性能改善

Improvement on Performance of the Direct Torque Control System of Induction Motor
下载PDF
导出
摘要 针对感应电动机直接转机控制系统工作原理,分析了感应电动机直接转矩控制系统转矩脉动大的原因,对感应电动机的电压表进行了改进。并利用Matlab/Simulink软件对感应电动机直接转矩控制系统改进前后进行了建模和仿真。 Based on the working principle of direct torque control system of induction motor, the reason of large torque ripple is analyzed and the voltage table of motor is improved. The modeling and simulation are carried out for the control system in pre-and post-improvement by Matlab/Simulink software.
作者 蒋晏强
出处 《防爆电机》 2009年第4期17-19,28,共4页 Explosion-proof Electric Machine
关键词 感应电动机 直接转矩控制 转子磁链角 Induction motor direct torque control rotor flux linkage angle
  • 相关文献

参考文献3

二级参考文献4

  • 1Takahashi I ,Noguchi T. A new quick-response and high-efficiency control strategy of an induction motor [ J ]. IEEE Trans on Industrial Applications, 1986,22 (5) :821 - 827.
  • 2Zhong L,Rahman M F. Analysis of direct torque control in permanent magnet drives [ J ]. IEEE Transactions on Power Electronics, 1997,12 ( 3 ) :528 - 535.
  • 3Chung D W,IEEE Trans Ind Appl,1998年,34卷,2期,374页
  • 4田淳,胡育文.永磁同步电机直接转矩控制系统理论及控制方案的研究[J].电工技术学报,2002,17(1):7-11. 被引量:130