摘要
介绍330MWe CFB锅炉外置换热器结构、工作原理及实际运行中良好的床温和汽温调节性能,并针对外置式换热器在运行中出现的问题提出切实可行的解决方法。
The structure, work principle & the bed temperate and steam temperature control characteristic of the external heat exchanger (EHE) of the 330MWe circulating fluidized bed (CFB) boiler are introduced in this paper. The feasible settlement methods of the EHE troubles are suggested .
出处
《锅炉制造》
2009年第4期24-26,共3页
Boiler Manufacturing
关键词
循环流化床锅炉
外置换热器
床温
汽温
circulating fluidized bed ( CFB ) boiler
external heat exchanger ( EHE )
bed temperate
steam temperature