摘要
详细分析了宁夏发电集团马莲台发电厂2×330MW发电机组配套设备磨煤机油站控制电源开关跳闸的原因,针对磨煤机油站控制电源系统中存在的问题,采取了相应的技术改造措施,并提出了一些改进性建议。
Analyzes the eause of controllable power source switch trip of the coal pulverizer oil station for 2×300 MW generating units in Maliantai Power Plant, aiming at the existing problems of controllable power source system at the coal pulverizer oil station, adopts the corresponding technical measures, puts forward some improving suggestion.
出处
《宁夏电力》
2009年第3期48-51,共4页
Ningxia Electric Power
关键词
磨煤机油站
控制电源开关
故障
对策
coal pulverizer oil station
controllable power source switch
failure