期刊文献+

电磁继电器触点磨损的理化分析 被引量:5

Physical and Chemical Analysis of Contact Points Wear of Electromagnetic Relay
下载PDF
导出
摘要 电磁继电器是各类自动化系统中重要的一种基础元件.由于它频繁工作在开关状态,外部振动或温度变化可能引起继电器触点表面氧化或磨损,从而电接触电阻增大,对电接触性能产生不良影响.借助扫描电镜(SEM)和X射线衍射仪(XRD)对电接触表面进行观察和测量.实验结果表明,经长期连续使用后触点表面变得粗糙并发生磨损,其组分中含有C、Ce、Ag等原子.最后对继电器早期失效机理进行了讨论. Electromagnetic relay is an essential element in various automatic systems.Because of freguent operation in the condition of on off state,external vibration or temperature rising may cause oxidation or wear of the surface of contact points.Therefore,the electrical contact resistance increased,which induced a bad effect on the electrical performance.The scanning electron microscopy(SEM) and X ray diffraction (XRD) were used to observe and measure the electrical contact surface.The experimental results show that the surface of contact points after continual operation for a long time became rough.The surface layer contained C,Ce,Ag elements etc.Thereafter the mechanism of efficacy losing of electromagnetic relay in early stage was discussed.
出处 《厦门大学学报(自然科学版)》 CAS CSCD 北大核心 1998年第3期368-373,共6页 Journal of Xiamen University:Natural Science
基金 厦门市产学研联合研究课题
关键词 电磁继电器 触点 磨损 理化分析 Electromagnetic relay,Contact points,Wear,Physical and chemical analysis
  • 相关文献

参考文献7

  • 1车晓舟.Ce对非晶态Fe_(76)B_(15)Si_9合金脆化及晶化的影响[J].材料研究学报,1995,9(4):313-316. 被引量:4
  • 2郑天丕,继电器制造·工艺·使用,1996年,30页
  • 3凯尔 A,电接触和电接触材料,1993年,1页
  • 4胡信国,稀土,1988年,6卷,25页
  • 5陆家和,表面分析技术,1987年,10页
  • 6Zhang J G,Proc IC-ECMAC,1986年,871页
  • 7范雄,金属X射线学,1981年,283页

二级参考文献1

  • 1余宗森,钢中稀土,1982年

共引文献3

同被引文献53

引证文献5

二级引证文献62

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部