结合钱清发电厂CEMS系统运行维护的经验,对预处理系统各组件的故障点进行了详细的剖析,给出了解决预处理系统故障的方法和改进措施,有效降低了CEMS系统故障率。
According to the experience of mantaining CEMS, the causes of faults in pre-treatment system of CEMS are explained in detail, also the ways of improvements are given. Finally occur-rate of the faults in CEMS are reduced effectively.