期刊文献+

绕击雷侵入波下1100kV电气设备的绝缘配合研究(英文) 被引量:1

Insulation Coordination Study of the 1100kV Equipment for Shielding Failure Surge
下载PDF
导出
摘要 用电气几何模型(A-W theory)和EMTP程序定量研究了中国特高压变电站设备的绝缘配合问题。与出厂雷电冲击试验电压波形不同,由绕击雷电侵入波在主变压器上产生的电压波形在波头有高频振荡且波尾时间长。考虑多重雷的绕击雷电侵入波,在线路入口安装瓷柱式避雷器和罐式避雷器可以更好地保护断路器和高抗。 This paper studies the insulation coordination of the UHV substation equipment in China quantitatively using the A-W theory and EMTP analysis method. The voltage waveform on the transformer terminal caused by shielding failure surge has high-frequency oscillation at the front with a long-tailed duration, which is absent in impulse test voltage at factories. Both porcelain and tank type of attesters installed at the line entrance are preferable to fully protecting gas circuit breaker (GCB) and shunt reactor (SHR) from multiple lightning shielding failure surge.
出处 《中国电机工程学报》 EI CSCD 北大核心 2009年第22期68-75,共8页 Proceedings of the CSEE
关键词 特高压 气体绝缘金属封闭开关设备 断路器 并联电抗器 变压器 绝缘配合 多重雷击 直击雷 绕击 罐式避雷器 瓷套式避雷器 UHV gas insulated switchgear gas circuit breaker shunt reactor transformer insulation coordination multiple lightning direct stroke shielding failure tank type surge arrester porcelain type surge arrester
  • 相关文献

参考文献6

  • 1Gu Dingxie, Zhou Peihong, Dai Min, et al. Study on lightning performance of 1 000kV AC transmission project[C]. International Conference of UHV Power Transmission Technology, Beijing, China, 2006.
  • 2Yamagata Y , et al . Technical background of insulation coordination in UHV system[C]. CIGRE Colloqium A3.22, Rio. Sept., 2007.
  • 3Zaima E, Okamoto H. System design and insulation coordination for UHV AC transmission system in TEPCO[C]. International Conference of UHV Power Transmission Technology, Beijing, China, 2006.
  • 4Chiba T, Kayano Y, Hirai K, et al. Consideration of surge arresters used for the UHV transmission systems in China[C]. International Conference of UHV Power Transmission Technology, Beijing, China, 2006.
  • 5Takami J, Okabe S. Characteristics of direct lightning strokes to phase conductors of UHV transmission lines[J]. IEEE Trans. on Power Delivery, 2007, 22(1): 537-546.
  • 6CIGRE Report. Guide to procedures for estimating the lightning performance of transmission lines[R]. 1991.

同被引文献20

引证文献1

二级引证文献7