期刊文献+

核素心肌灌注显像与电子束CT诊断冠心病的对比研究 被引量:4

A comparative study of ^(99m)TcMIBI SPECT and EBCT in diagnosis of coronary heart disease
下载PDF
导出
摘要 目的比较核素心肌SPECT显像与电子束CT(EBCT)扫描对冠心病(CHD)的诊断价值。方法对64例受检者(CHD患者50例,非CHD患者14例)进行了冠状动脉造影、SPECT及EBCT检查。结果以冠状动脉造影为金标准,SPECT与EBCT诊断CHD的灵敏度相近,分别为920%和940%;SPECT的特异性(929%)优于EBCT(286%),P<005。在判断EBCT结果时,采用不同的钙化积分阈值,对诊断CHD的灵敏度和特异性影响很大,故应采用接收器工作特性分析确定适当的钙化积分阈值。结论EBCT虽具有一定优越性,但目前尚不能取代心肌SPECT显像。 Purpose To comparatively study ^(99m)TcMIBI SPECT and electron beam CT (EBCT) in diagnosing coronary heart disease (CHD) Methods 64 patients (54 men, 10 women; mean age 59.7years) underwent SPECT, EBCT and cononary arteriography within one month Results Using coronary arteriographic findings as gold standard, the sensitivities of SPECT and EBCT for diagnosing CHD were 92.0% and 94.0%, the specificities were 92.9% and 28.6%, respectively The sensitivity and specificity of EBCT for diagnosing CHD were varying with different threshold limits used for coronary calcification scoring Receiver operating characteristic analysis should be used to define the appropriate threshold limit for coronary calcification scoring Conclusions EBCT is of some advantages, but should not be used in place of SPECT in diagnosis of CHD
出处 《中华核医学杂志》 CAS CSCD 北大核心 1998年第3期156-158,共3页 Chinese Journal of Nuclear Medicine
关键词 冠心病 CT 放射性核素显像 Coronary disease Tomography, emission computed, single photon Tomography, X-ray computed