依据传热基本原理,对保温室体热性能参数进行非稳态(升温、降温)理论分析,实现了温室隔热体传热系数及蓄热当量系数的非稳态测量。利用数学处理,提出了准确实用的试验测量方法并进行了试验验证。
Based on the principle of heat transfer,the dynamic thermal characteristic(temperature up and down)factors of passive solar housing system,transient heat transfer and equivalent heat storage coefficient measurement model were established.With the aid of mathematical analysis,measuring method is presented and got test verification.