摘要 在依据第二制冷剂量热计法设计搭建的0.6~35kW制冷量全自动压缩冷凝机组性能测试系统中,通过优化量热器和管路设计并采用模糊自适应PID控制代替目前常用的PID控制,解决了系统测试冷量范围大P、I、D参数整定困难以及被控参数互相耦合导致吸气温度和吸气压力无法同时达到稳定的问题,实现了对制冷系统中吸气温度及吸气压力的精确控制,使参数控制精度满足标准JB/T9056—1999对压缩冷凝机组性能测试的要求,并给出了该系统模糊A适应PID控制的基本设计过程。 An automatic experimental system was introduced, which can test the performance of refrigeration compression condensing unit with 0.6 - 35kW wide range of cooling capacity in which the fuzzy adaptive PID is applied to the control system instead of traditional PID control. The application of fuzzy adaptive PID solves the unstable problem of suction temperature and suction pressure which is caused by intercoupling and the difficult problem of adjusting PID parameter for different testing conditions is also solved. The main design process of the fuzzy adaptive PID is introduced .
机构地区 上海理工大学
出处 《流体机械》 CSCD 北大核心 2009年第7期77-81,共5页 Fluid Machinery
基金 上海市重点学科建设项目(S30503)
关键词 性能测试 吸气温度 吸气压力 耦合 模糊自适应PID performance test suction temperature suction pressure intercoupling fuzzy adaptive PID
  • 相关文献

参考文献7

二级参考文献11

共引文献13

同被引文献27

  • 1袁亚周,涂淑平.制冷压缩冷凝机组性能测试室研究[J].机电设备,2006,23(2). 被引量:6
  • 2Craig Wray, Hashem Akbari. The effects of roof reflectance on air temperatures surrounding a rooftop condensing unit[ J]. En- ergy and Buildings ,2008 ( 40 ) : 11-28.
  • 3Chow T T, Lin Z, Yang X Y. Placement of condensing units of split-type air-conditioners at low-rise residences[ J ]. Applied Thermal Engineering,2002 (22) : 1431-1444.
  • 4Chow T T, Lin Z, Wang Q W. Effect of building re-entrant shape on performance of air-cooled condensing units [ J ]. Energy and Buildings, 2000 (32) : 143-152.
  • 5艾默生环境优化(苏州)研发有限公司,等.GB/T21363—2008,容积式压缩冷凝机组[S].中国国家标准化管理委员会,2008.
  • 6Directive 2009/125/EC of the European Parliament and of the Council of 21 October 2009 establishing a frame- work for the setting of ecodesign requirements for energy - related products[ EB/OL~. [ 2009 - 10 - 31 ]. http:// cur - lex. europa, eu/LexUriServ I J ]/LexUriServ. do uri = OJ : L : 2009 : 285:0010:0035 : EN : PDF.
  • 7中国国家标准化管理委员会.GB/T21363-2008容积式制冷压缩冷凝机组[S].北京:中国标准出版社,2008.
  • 8Mohanraj M, Jayaraj S, Muraleedharan C. Environment friendly alternatives to halogenated refrigerants -A re- view[J]. International Journal of Greenhouse Gas Con- trol ,2009,3 ( 1 ) : 108 - 119.
  • 9Navarro E, Martnez -Galvan I O, Nohales J, et al. Com- parative experimental study of an open piston compressor working with R- 1234yf, R- 134a and R-290[J]. Inter- national Journal of Refrigeration,2013. 36(3) :768 -775.
  • 10翟旭升,谢寿生,杨伟,蔡开龙.基于自适应模糊PID控制的恒压供气系统[J].液压与气动,2008,32(2):21-23. 被引量:16

引证文献3

二级引证文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部