X射线显微CT成像的图像实时校正研究 被引量:5

Investigation of Online Image Distortion Corrections for X-ray Micro-CT Imaging
下载PDF
导出
摘要 针对我们研制的小动物活体成像的X射线显微CT系统,研究了显微CT成像的图像实时校正问题,分别对探测器固有缺陷引起的像素响应失真及锥形成像几何造成的光照不均匀进行了分析,提出了校正方案,并实现了图像实时在线校正。初步的实验结果显示,该方案有很好的校正效果,取得了满意的成像质量,能满足实时性工作需求,可以推广应用于其它类似显微CT成像的图像实时校正。 The aim of the study was to investigate the online image distortion corrections for our X-ray micro-CT system for high-resolution small animal imaging. The distortions of rnicro-CT imaging due to the detector's intrinsic defects and the nonuniform irradiation of the cone-beam geometry were analyzed. The correction method for those image distortions was then developed and implemented with online image acquisition. The preliminary experiments show that our correction method is reliable and effective to correct those image distortions from the projection images. This image correction method could be utilized for other similar micro-CT systems.
出处 《核电子学与探测技术》 CAS CSCD 北大核心 2009年第4期910-913,共4页 Nuclear Electronics & Detection Technology
关键词 显微CT 图像校正 micro CT, image correction
  • 相关文献

参考文献8

二级参考文献39

  • 1严军,陈迎娟.基于光电响应模型的CCD像素响应不均匀性校正方法[J].宇航计测技术,2004,24(6):20-25. 被引量:5
  • 2李军,朱德生,包尚联.显微CT技术及其在生物医学领域的应用[J].现代仪器,2009,15(6):19-23. 被引量:11
  • 3Fox E C,Agwani S,Dykaar D R,et al.A high speed linear CCD sensor with pinned photodiode photosite forlow lag and low noise imaging.SPIE,1998,3301:17-26
  • 4Gamal E I,Abbas,Fowler Boyd,et al.Modeling and estimation of FPN components in CMOS image sensors.SPIE,1998,3301:168-177
  • 5Zhao W, Rowlands JA. A x-ray imaging using amorphous selenium:Feasibility of flat panel self scanned detector for digital radiography. Med. Phys., 1995,22(10):1595~1604.
  • 6Lee DL, Cheung LK, Jeromin LS, Palecki EF, Rodricks B. Radiographic imaging characteristics of a direct conversion detector using selenium and thin film transistor array. Proc. SPIE,1997,3032:88~95.
  • 7Lee DL, Cheung LK, Rodricks BG, Powell GF. Improved imaging performance of a 14×17-in. direct radiography system using a Se/TFT detector. Proc. SPIE 1998,3336:14~23.
  • 8Seibert JA, Boone JM, et al.. Flat-field correction technique for digital detectors. Proc. SPIE,1998,3336:348~354.
  • 9Bruijns TJ, Alving PL, et al.. Technical and clinical results of an experimental flat dynamic (digital) X-ray image detector (FDXD) system with real-time corrections. Proc.SPIE,1998,3336:33~44.
  • 10Antonuk LE, Boudry J, Huang W. Demonstration of megavoltage and diagnostic x-ray imaging with hydrogenated amorphous silicon array. Med. Phys., 1992,19:1455~1466.

共引文献46

同被引文献75

引证文献5

二级引证文献23

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部