期刊文献+

离子吸附质谱中锂离子源的研制(英文)

Development of alkali ion source for Li^+ ion-attachment mass spectrometry
下载PDF
导出
摘要 研制并测试了一种用在离子吸附质谱中的锂离子源.这个离子源是通过在一个高真空管中,将Li2O.Al2O3.SiO2熔结在金属铼丝带上制备而成.考虑到离子源使用的耐久性及锂离子发射量,实验确定了最佳的铼丝温度为1 300℃.通过使用飞行时间质谱,大量的锂离子被检测到,表明研制的锂离子源能够用在质谱分析中. A kind of lithium ion source used for ion attachment mass spectrometry was fabricated and tested. The lithium ion source was made using a Re ribbon filament coated with Li2O · Al2O3 · SiO2, which was developed in a high vacuum chamber. The filament temperature of 1300℃ was decided in consideration of the effects of the durability of the filament and the quantity of the lithium ions. The copious lithium ions were detected using a time of flight mass spectrometry. It showed the applicability of the lithium ion source in mass spectrometry.
作者 常薇
出处 《西安工程大学学报》 CAS 2009年第2期602-605,共4页 Journal of Xi’an Polytechnic University
关键词 锂离子 离子源 质谱 lithium ion emitter mass spectrometry
  • 相关文献

参考文献5

  • 1HORIUCHI M,FUKUSHIGE T,SAHEKI T,et.al.Improved matrix-assisted laser desorption/ionization time-of-flight mass spectrometric method for identification of amino acid O-Glycosides in patients with N-Acetylgalactoasminidase deficiency[J].Clinical Chemistry,2002,48:1 798-1 799.
  • 2CHRISTOPHER P Selvin,FUJII T.Lithium ion attachment mass spectrometry:Instrumentation and fcatrures[J].Review of Scientific Instruments,2001,72:2 248-2 252.
  • 3FUJII T,CHRISTOPHER P Selvin,et al.Lithium ion attachment mass spectrometry for on-line analysis of trace components in air:direct introduction[J].International Journal of Mass Spectrometry,2001,209:39-45.
  • 4FAYE T,BRUNOT A.Sodium ion attachment reactions in an ion trap mass spectrometer[J].Rapid Communications in Mass Speetrometry,2000,14:1 066-1 073.
  • 5FUJII T.Alkali-metal ion/molecule association reactions and their applications to mass spectrometry[J].Mass Spectrometry Reviews,2000,19:111-138.