期刊文献+

髋臼后柱钢板内固定技术的解剖学研究 被引量:10

Clinical anatomic study of internal fixation of acetabular posterior column plate technique
原文传递
导出
摘要 目的研究髋臼后柱钢板内固定技术中螺钉的最佳进钉点、方向和长度,预防螺钉穿人关节内的严重并发症。方法2008年2月至7月取成年男性半骨盆标本20个,制作髋臼后柱系列断面,测量各进钉点的螺钉进钉角度和长度,将测量数据输入到SPSS10.0进行统计学分析。结果各断面在髋臼缘、外中1/4点、中点、内中1/4点和后柱内缘的进钉安全角度分别为39°、57°、74°、90°和106°,螺钉长度分别为39、57、74、90和106mm。结论在髋臼区的外1/4区、外中1/4区、内中1/4区和在内1/4区,钉后柱角分别为40°至60°、60°至75°、75°至90°、90。至平行于四方区,螺钉长度30mm。 Objectives To study the best entry points, direction and length of screw in acetabular posterior column plate technique, and to prevent the serious complications of screw penetrating the joint surface. Methods February to July 2008 20 male cadaveric adult semipelvic specimen were taken. Serial cross-sections of the acetabular posterior column were determined and made. The safe angle of screw entry and the length on all entry points of each cross-section were measured. And put all data into software SPSS 10. 0 for statistics process. Results On margin of acetabulum, lateral-middle 1/4 point, midpoint, medialmiddle 1:/4 point and medial margin of posterior column of each cross-section, safe entry angle of inclination was 39° ,57°, 74°, 90° and 106° respectively, the length of the screw was 39, 57, 74, 90 and 106 mm respectively. Conclusion On lateral 1/4 region, lateral-middle 1:/4 region, medial-middle 1/4 region and medial 1:/4 region, screw posterior column angle is 40°to 60°, 60°to 75°, 75°to 90°, 90°to parallel to the quadrilateral plate, and the length of the screw is 30 mm.
出处 《中华外科杂志》 CAS CSCD 北大核心 2009年第15期1182-1184,共3页 Chinese Journal of Surgery
基金 中国博士后科学基金资助项目(20070421096)
关键词 髋骨折 骨折固定术 解剖 后柱钢板 Hip fractures Fracture fixation,internal Anatomy Posterior column plate
  • 相关文献

参考文献7

二级参考文献21

  • 1王先泉,张进禄,周东生.沿骨盆界线放置内固定物的临床解剖学研究[J].中国临床解剖学杂志,2005,23(2):153-156. 被引量:15
  • 2潘兵,张光健.髓臼区的横断断层解剖及临床意义[J].中国临床解剖学杂志,1994,12(2):138-140. 被引量:8
  • 3Tile M.Fractures ofthe pelvis and acetabrlum Second edition.Baltimore:Williams&Wilkins,1995.387 391
  • 4Letournel E, Judet R. Fracture of the acetabulum. 2nd ed. New York:Springer-Verlag,1993.536-565.
  • 5Brooker AF, Bowerman JW, Robinson RA, et al.Ectopic ossification following total hip replacement:incidence and a method of classification. J Bone Joint Surg(Am),1973,55:1629-1632.
  • 6Tile M. Fractures of the acetabulum.In:Rockwood CA,Green DP,Bucholz RW,eds.Fractures in adults. 4th ed.Philadephia:Lippincott-Raven,1996.1657-1658.
  • 7Calder HB, Mast J, Johnstone C.Intraoperative evoked potential monitoring in acetabular surgery. Clin Orthop,1994,(305):160-167.
  • 8Matta JM,Anderson LM. Fracture of the acetabulum.Clin Orthop,1986,(205):230-240.
  • 9Calandruccio RA,Anderson WE.Post-fracture avascular necrosis of the femoral head: correlation of experimental and clinical studies.Clin Ortnop,1980,(152):49-84.
  • 10Mclaren AC.Prophylaxis with indomethacin for heterotopic bone: after open reduction of fractures of the acetabulum. J Bone Joint Surg(Am),1990,72:245-247.

共引文献200

同被引文献85

引证文献10

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部