适应性支持通气在呼吸衰竭中的应用 被引量:2

The effect of the adaptive support ventilation in respiratory failure
下载PDF
导出
摘要 目的:探讨适应性支持通气(ASV)在呼吸衰竭患者中的临床价值。方法:选择需要机械通气的呼吸衰竭患者58例,将其随机分为两组,观察组(ASV)29例,对照组29例采用同步间竭指令通气+压力支持通气(SIMV+PSV),两组同时进行机械通气治疗直至撤机,记录比较两种模式下的各项呼吸力学及血流动力学参数、血气分析、舒适程度、通气时间和撤机成功率。结果:全部患者均成功脱机,呼吸频率明显下降,潮气量(VT)明显升高(P<0.05),气道峰压(Ppeak)和吸气阻力(R)下降显著(P<0.05),静脉顺应性(Cstat)逐渐增加(P<0.05)。ASV通气患者的上机时间明显缩短(P<0.05)。结论:ASV可根据患者的呼吸力学状况自动调整吸气压力支持水平,提高潮气量,降低呼吸频率,而对血流动力学和生命体征没有影响,并能缩短上机时间,明显优于常规通气,而且操作简单,值得临床大力推广应用。 Objective:To investigate the clinical value of the adaptive support ventilation (ASV) in patients with respiratory failure. Methods: 58 cases with respiratory failure needed mechanical ventilation were randomly divided into two groups, the observation group (ASV) for 29 cases, 29 cases of the control group between synchronized mandatory ventilation exhaust ventilation + pressure support (SIMV + PSV), two groups at the same time mechanical ventilation until weaning, compared records of the two modes of respiratory mechanics and hemodynamic parameters, blood gas analysis, comfort, ventilation time and the success rate of weaning. Results:All patients were successfully offline, significantly reduced respiratory frequency, tidal volume (VT) increased significantly (P〈0.05), peak airway pressure (Ppeak) and inspiratory resistance (R) decreased significantly (P〈0.05), intravenous compliance (Cstat) gradually increased (P〈0.05). ASV machine ventilation on patients with significantly shortened (P〈0.05). Conclusion:ASV under conditions of respiratory mechanics in patients with auto-adjust at the level of inspiratory pressure support and enhance tidal volume, reducing respiratory rate, and on hemodynamies and do not affect vital signs, and can shorten the time the machine, it is obviously superior to conventional ventilation, and easy to operate and is worth to promote the clinical application.
出处 《中国当代医药》 2009年第15期56-58,共3页 China Modern Medicine
关键词 适应性支持通气 呼吸衰竭 机械通气 Adaptive support ventilation Respiratory failure Mechanical ventilation
  • 相关文献

参考文献4

二级参考文献17

  • 1詹庆元,王辰,黄克武.自动调节通气频率和潮气量通气模式的临床应用研究[J].中国呼吸与危重监护杂志,2002,1(4):215-216. 被引量:13
  • 2张红远.微风型E-150呼吸机的常见报警[J].医疗卫生装备,2006,27(10):103-104. 被引量:2
  • 3孙念军.呼吸机常见故障的排除[J].医疗卫生装备,2006,27(10):104-105. 被引量:17
  • 4Laubscher TP, Frutiger A, Fanconi S, et al. The automatic selection of ventilation parameters during the initial phase of mechanical ventilation. Intensive Care Med, 1996,22: 199- 207.
  • 5Linton DM, Potgieter PD, Davis S, et al. Automatic weaning from mechanical ventilation using an adaptive lung ventilation controller. Chest, 1994, 106:1843 - 1850.
  • 6Cassina T, Chiolem R, Mauri R, et al. Clinical experience with adaptive support ventilation for fast-track cardiac surgery. J Cardiothorac Vasc Anesth, 2003 , 17 : 571 - 575.
  • 7Belliato M, Palo A, Pasero D, et al. Evaluation of adaptive support ventilation in paralysed patients and in a physical lung model. Int J Arif Organs,2004,27:709 - 716.
  • 8Otis AB, Fenn WO, Rahn H. Mechanics of breathing in man. J Appl Physiol, 1950, 2: 592 - 607.
  • 9Hewlett AM,Platt AS,Terry VG.Mandatory minute volume[R].Aneaathesia:A new concept in weaning from mechincal ventilation,1997:163-169.
  • 10拉斐尔呼吸机操作维护手册[R].瑞士:夏美顿,2003:补7-补33.

共引文献24

同被引文献10

引证文献2

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部