摘要
对某厂高纯氮原输送气路进行了分析,针对该厂高纯氮的使用情况及管网布置情况,提出了新的管网布置方案和节能降耗方法,对原回路进行了重新设计改造,并就改造后的回路进行了节能效果分析和计算。
The delivery way of high purity nitrogen of a factory was analyzed. According to the using condition of high purity nitrogen and the pipe network, a new pipe network scheme and a new method of energy saving were put forward. The delivery way of high purity nitrogen was redesigned, and the effect of energy saving was analyzed and calculated.
出处
《机床与液压》
北大核心
2009年第8期268-270,212,共4页
Machine Tool & Hydraulics
关键词
高纯氮
气压回路
改造
High purity nitrogen
Pneumatic circuit
Reform