摘要
AIM: To examine the technical feasibility and clinical outcomes of the endoscopic insertion of a selfexpandable metal stent (SEMS) for the palliation of a malignant anastomotic stricture caused by recurrent gastric cancer. METHODS: The medical records of patients, who had obstructive symptoms caused by a malignant anastomotic stricture after gastric surgery and underwent endoscopic insertion of a SEMS from January 2001 to December 2007 at Kangnam St Mary's Hospital, were reviewed retrospectively. RESULTS: Twenty patients (15 male, mean age 63 years) were included. The operations were a total gastrectomy with esophagojejunostomy (n = 12), subtotal gastrectomy with Billroth-Ⅰ reconstruction (n = 2) and subtotal gastrectomy with Billroth- Ⅱ reconstruction (n = 8). The technical and clinical success rates were 100% and 70%, respectively. A small bowel or colon stricture was the reason for a lack of improvement in symptoms in 4 patients. Two of these patients showed improvement in symptoms after another stent was placed. Stent reobstruction caused by tumor ingrowth or overgrowth occurred in 3 patients (15%) within 1 mo after stenting. Stent migration occurred with a covered stent in 3 patients who underwent a subtotal gastrectomy with Billroth-Ⅱ reconstruction. Two cases of partial stent migration were easily treated with a second stent or stent repositioning. The median stent patency was 56 d (range, 5-439 d). The median survival was 83 d (range, 12-439 d). CONCLUSION: Endoscopic insertion of a SEMS provides safe and effective palliation of a recurrent anastomotic stricture caused by gastric cancer, A meticulous evaluation of the presence of other strictures before inserting the stent is essential for symptom improvement.
AIM:To examine the technical feasibility and clinical outcomes of the endoscopic insertion of a self-expandable metal stent(SEMS) for the palliation of a malignant anastomotic stricture caused by recurrent gastric cancer.METHODS:The medical records of patients, who had obstructive symptoms caused by a malignant anastomotic stricture after gastric surgery and underwent endoscopic insertion of a SEMS from January 2001 to December 2007 at Kangnam St Mary's Hospital, were reviewed retrospectively.RESULTS:Twenty patients(15 male, mean age 63 years) were included.The operations were a total gastrectomy with esophagojejunostomy(n = 12), subtotal gastrectomy with Billroth-—migration occurred with a covered stent in 3 patients who underwent a subtotal gastrectomy with Billroth-reconstruction.Two cases of partial stent migration were easily treated with a second stent or stent repositioning.The median stent patency was 56 d(range, 5-439 d).The median survival was 83 d(range, 12-439 d).CONCLUSION:Endoscopic insertion of a SEMS provides safe and effective palliation of a recurrent anastomotic stricture caused by gastric cancer.A meticulous evaluation of the presence of other strictures before inserting the stent is essential for symptom improvement.