期刊文献+

Applicability and variability of liver stiffness measurements according to probe position 被引量:5

Applicability and variability of liver stiffness measurements according to probe position
下载PDF
导出
摘要 AIM: To investigate the liver stiffness measurement (LSM) applicability and variability with reference to three probe positions according to the region of liver biopsy. METHODS: The applicability for LSM was defined as at least 10 valid measurements with a success rate greater than 60% and an interquartile range/median LSM < 30%. The LSM variability compared the inter-position concordance and the concordance with FibroTest. RESULTS: Four hundred and forty two consecutive patients were included. The applicability of the anterior position (81%) was significantly higher than that of the reference (69%) and lower positions (68%), (both P = 0.0001). There was a signif icant difference (0.5 kPa, 95% CI 0.13-0.89; P < 0.0001) between mean LSM estimated at the reference position (9.3 kPa) vs the anterior position (8.8 kPa). Discordance between positions was associated with thoracic fold (P = 0.008). The discordance rate between the reference position result and FibroTest was higher when the 7.1 kPa cutoff was used to define advanced fibrosis instead of 8.8 kPa (33.6% vs 23.5%, P = 0.03).CONCLUSION: The anterior position of the probe should be the fi rst choice for LSM using Fibroscan, as it has a higher applicability without higher variability compared to the usual liver biopsy position. AIM: TO investigate the liver stiffness measurement (LSM) applicability and variability with reference to three probe positions according to the region of liver biopsy. METHODS: The applicability for LSM was defined as at least 10 valid measurements with a success rate greater than 60% and an interquartile range/median LSM 〈 30%. The LSM variability compared the inter-position concordance and the concordance with FibroTest. RESULTS: Four hundred and forty two consecutive patients were included. The applicability of the anterior position (81%) was significantly higher than that of the reference (69%) and lower positions (68%), (both P = 0.0001). There was a significant difference (0.5 kPa, 95% CI 0.13-0.89; P 〈 0.0001) between mean LSM estimated at the reference position (9.3 kPa) vs the anterior position (8.8 kPa). Discordance between positions was associated with thoracic fold (P = 0.008). The discordance rate between the reference position result and FibroTest was higher when the 7.1 kPa cutoff was used to define advanced fibrosis instead of 8.8 kPa (33.6% vs 23.5%, P = 0.03).CONCLUSION: The anterior position of the probe should be the first choice for LSM using Fibroscan, as it has a higher applicability without higher variability compared to the usual liver biopsy position.
出处 《World Journal of Gastroenterology》 SCIE CAS CSCD 2009年第27期3398-3404,共7页 世界胃肠病学杂志(英文版)
关键词 FIBROSCAN Fibrotest Liver fibrosis VARIABILITY CONCORDANCE 硬度测量 适用性 肝脏 可变性 探头位置 测量范围 一致性 肌病
  • 相关文献

参考文献1

二级参考文献2

共引文献32

同被引文献26

引证文献5

二级引证文献35

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部