本文根据热电偶配用补偿导线的测温原理,进行了测温误差分析,给出了镍铬-镍硅(铝)热电偶配用铜-康铜补偿线的测温误差修正值,并经实验验证。
On the basis of the principle of temperature with compensation lead,this paper presents the error analysis and correction method for temperature measurement of a thermocoupe with compensation lead.The correction temperature value of the type of k(NiCr-NiSi)thermocouple with copper-constantan lead was presented.It was tested by experiment.
出处
《仪表技术与传感器》
CSCD
北大核心
1998年第6期31-34,共4页
Instrument Technique and Sensor
关键词
温度测量
误差分析
热电偶
补偿导线
Temperature Measurement,Error Analysis and Correction,Thermocouple and Compensation Lead.