作为化学氧碘激光器(COIL)的能量来源,O2(1Δ)发生器(SOG)工作状态直接影响COIL的工作性能,而碱性过氧化氢溶液的稳定与否又影响SOG的工作状态。通过对转盘式SOG实验中BHP配制及稳定操作的系统研究,提出了造成BHP溶液不稳定的几种原因及相关的解决方法。
The performance of Singlet Oxygen Generator(SOG) as energy source of COIL determine the performance of COIL immediately,but the stability of BHP influence the stability of SOG. The environment of BHP preparation and working conditions were discussed.In the last,the related method to prevent BHP from unstable operation was given.
出处
《强激光与粒子束》
EI
CAS
CSCD
北大核心
1998年第3期454-456,共3页
High Power Laser and Particle Beams
基金
国家863激光技术领域资助
关键词
BHP配制
稳定操作
化学氧碘激光器
BHP preparation, stability operation, Singlet Oxygen Generator(SOG), COIL