摘要
介绍了在网络等值化简基础上搭建的适合于研究交直流交互影响的华东电网电磁暂态仿真数据平台。通过仿真对称和不对称交流故障激发直流换相失败,提取换相失败的临界条件,作为直流准稳态模型换相失败的判断标准。研究表明对于对称和不对称故障应采用不同的换相失败判断标准。认为采用电磁暂态仿真方法整定机电暂态中直流换相失败的判断标准具有开创性,对开展机电环境下交直流交互影响研究具有一定的指导意义。
Based on network equivalence, an electromagnetic transient simulation platform suitable for studying interaction between AC and DC systems was built. The commutation failure scenarios were simulated by symmetrical and asymmetry faults, and then the critical conditions of commutation failures were extracted as commutation failure criteria. The study indicated that different commutation failure criteria should be adopted for symmetrical and asymmetry faults respectively.
出处
《华东电力》
北大核心
2009年第7期1157-1160,共4页
East China Electric Power
关键词
换相失败
电磁暂态
准稳态模型
动态等值
华东电网
特高压直流
特高压交流
commutation failure
electromagnetic transient
quasi-steady-state model
dynamic equivalence
East China Power Grid
UHVDC
UHVAC