摘要
提出并实现了用相干自混频方法监测马赫-曾德尔调制器(MZM)零偏置点漂移,将同一光源所产生的部分未调制光和调制后的光进行混频,利用混频光功率的最大最小值之比作为监测量监测。相比于监测信号光平均光功率的方法,可使±5%偏置点漂移下的灵敏度从0.02 dB提高到0.3 dB。利用设计完成的硬件反馈控制系统进行了多次实验,讨论了影响系统工作的各种因素及相应的解决办法,结果表明该方法工作有效。
A method called coherent hybrid is proposed to monitor the bias offset drift of Mach-Zehnder modulator (MZM) by mixing the unmodulated local oscillation lightwave with the modulated signal from the same light source and measuring the hybrid power ratio of the maximum to the minimum. The sensitivity at ± 5% bias offset is improved from 0.02 dB to 0.3 dB compared with the traditional method by measuring the signal average power. Experiments are carried out with the developed feedback and control system based on this scheme to find the impairment factors and explore the proper solutions. The results reveal the feasibility and effectiveness of the method.
出处
《中国激光》
EI
CAS
CSCD
北大核心
2009年第8期2035-2041,共7页
Chinese Journal of Lasers
基金
国家973计划(2006CB302805)
国家863计划(2009AA01Z223
2009AA012253)资助项目
关键词
光通信
相干混频
信号监测
马赫-曾德尔调制器
偏置点控制
control optical communication
coherent hybrid
impairment monitoring
Mach-Zehnder modulator
bias