期刊文献+

超超临界机组水冷壁高温腐蚀问题的探讨 被引量:17

High Temperature Corrosion of Water Cooling Wall of Extrasupercritical Units
下载PDF
导出
摘要 介绍了国内首台超超临界机组水冷壁发生高温腐蚀的基本情况。对水冷壁管进行外观检查、金相分析和能谱微区成分分析,结果表明,管子外表面存在高温硫腐蚀,对发生腐蚀的原因作了探讨,并提出了预防措施。 The basic status of high temperature corrosion of water cooling wall of the first domestic extrasupercritical (ESC) units is introduced. A water cooling wall tube was analyzed by means of macroscopy inspection, metallograpy analysis and EDS. The results showed that there was high temperature sulfur corrosion on outside surface of the water cooling wall tube. The corrosion reasons are discussed, and some prevention measures are presented.
出处 《腐蚀与防护》 CAS 北大核心 2009年第8期577-578,588,共3页 Corrosion & Protection
关键词 超超临界机阻 水冷壁 高温腐蚀 预防措施 extrasupercritical(ESC) unit water cooling wall high temperature corrosion prevention measure
  • 相关文献

参考文献2

二级参考文献8

  • 1徐夕仁 马春元 等.有关1000t/h锅炉水冷壁高温腐蚀几个问题的探讨[M].,-..
  • 2李万详.EП670/140型锅炉水冷壁管烟侧腐蚀原因分析[J].电力技术,1984,(12).
  • 3钱垂喜.谏壁发电厂1000t/h直流锅炉水冷壁烟侧高温腐蚀原因的试验研究[J].热力发电,1988,(6).
  • 4-.宝鸡发电厂2号炉防止高温腐蚀的燃烧调整[J].锅炉技术,1977,(1).
  • 5许传凯.关于液态排渣锅炉若干问题的探讨[J].锅炉技术,1977,(9).
  • 6.锅炉爆管原因查证与改进措施手册[Z].美国电力研究院,..
  • 7董富,刘洪,李薇,马新家.燃煤锅炉水冷壁高温腐蚀及防护[J].节能技术,1997,15(3):29-31. 被引量:2
  • 8赵晴川.水冷壁烟气侧高温腐蚀的试验分析[J].华东电力,1998,26(7):10-13. 被引量:11