期刊文献+

基于MIDAS/GEN的框架结构PUSHOVER分析

A FRAME STRUCTURE PUSHOVER ANALYSIS BASED ON MIDAS/GEN
下载PDF
导出
摘要 通过MIDAS/GEN有限元分析软件对6层框架结构进行静力弹塑性分析,使用两种不同的加载工况来研究结构性能;结果表明,静力弹塑性分析方法是目前对结构进行罕遇地震作用下弹塑性分析较为有效的方法。 Based on the finite element software MIDAS/GEN , a 6-story reinforced concrete frame structure is analyzed through nonlinear static analysis under rare earthquake in this paper, use two load conditions to study structure performance ; According to the result, nonlinear static analysis is a effective method of structural elastoplastic analysis under rare earthquake action.
出处 《建筑技术开发》 2009年第8期7-9,共3页 Building Technology Development
关键词 静力弹塑性分析 框架结构 加载工况 结构性能 lonlinear static analysis frame structure load condition structure performance
  • 相关文献

参考文献4

  • 1MIDAS-GEN用户手册.北京迈达斯技术有限公司.
  • 2FEMA" NEHRP Guidelines for the Seismic Rehabilitation of Building" [ R], FEMA - 273, Washigton D. C. , 1997.
  • 3ATC, "Seismic Evaluation and Retrofit of Concrete Building" [ R ], Report No. ATC - 40. Applied Technology Council, Redwood City, California, 1996.
  • 4李毅,滕海文,霍达.粘滞阻尼器不同连接方式的减震性能研究[J].工程抗震与加固改造,2008,30(6):60-63. 被引量:8

二级参考文献3

  • 1Soong T T and Dargush G F. Passive Energy Dissipation System in Structural Engineer[ R]. State University of New York at Buffalo, 1997
  • 2Michael C Constantinou. Toggle-brace-damper Seismic Energy Dissipation Systems [ J ]. Journal of Structural Engineering, 127(2) : 105- 112
  • 3Ani N S and Michael C C. Scissor-Jack-Damper Energy Dissipation System [ J ]. Earthquake Spectra, 2003,19 ( 1 ) : 133 - 158