摘要 本文对兰州市41间集中供热的办公房间的冬季室内空气干球温度、相对湿度、风速等热环境参数进行了现场测试,同时以问卷方式对ASHRAE的7级热舒适指标进行了调查。结果表明,81%的办公人员对室内19.5℃的平均温度表示接受。而后通过编程计算热舒适指标PMV-PPD,得出兰州冬季供暖条件下80%的人感到舒适的温度范围为17—24℃,最佳室内空气参数为干球温度21℃,相对湿度20%。 In this paper, the filed measurement of indoor thermal environment parameters ,such as air temperature, relative humidity and air velocity, was carried out in 41 offices with central heating system in Lanzhou in winter. At the same time, thermal comfort indexes with seven orders that established by ASHRAE were investigated with questionnaires. The results demonstrated that 81% people felt comfortable at an average temperature of 19.5 ℃. Furthermore, based on the calculation of PMV-PPD indexes, it was concluded that 80% people felt comfortable at a temperature range from 17 ℃ to 24 ℃,and the optimal indoor parameters were of 21 ℃ and 20% RH.
出处 《建筑科学》 北大核心 2009年第8期94-97,108,共5页 Building Science
关键词 办公房间 热舒适 PMV-PPD指标 office, thermal comfort, PMV-PPD indexes
  • 相关文献

参考文献10

  • 1李俊鸽,杨柳,刘加平.夏热冬冷地区夏季住宅室内适应性热舒适调查研究[J].四川建筑科学研究,2008,34(4):200-205. 被引量:28
  • 2甘肃年鉴编委会.甘肃年鉴2007[M].北京:中国统计出版社.2007.
  • 3中华人民共和国建设部.GB50178-1993民用建筑热工设计规范[S].北京:中国计划出版社,1993.
  • 4国家质量技术监督局.GB/T18977-2003公共场所风速,空气温度,空气湿度测定方法[S].北京:中国标准出版社,2005.
  • 5中华人民共和国卫生部,国家环境保护总局.GB/T18883-2002室内空气质量标准[S].北京:中国环境科学出版社,2003
  • 6中国标准研究中心.GB/T18204-2000热环境人类工效学·使用主观判定量表评价热环境的影响[S].北京:中国计划出版社,1993.
  • 7国家质量技术监督局.GB/T18049-2000中等热环境PMV和PPD指数的测定及热舒适条件的规定[S].北京:中国标准出版社,2001.
  • 8Mccullough EA, Olesen BW, Hong S. Thermal insulation provided by chairs[ J]. ASHRAE Transactions, 1994,100( 1 ) : 795 - 802.
  • 9中国有色工程设计研究总院.GB50019-2003采暖通风与空气调节设计规范[S].北京:中国计划出版社,2004.
  • 10ASHRAE Standard 55-2002. Thermal Environmental Conditions for Human Occupancy [ S ]. Atlanta: American Society of Heating, Refrigerating and Air Conditioning Engineers, Ine, 2002.

二级参考文献5

  • 1Humphreys M A. Field studies of thermal comfort compared and applied. Building Research Establishment Current Paper Paper 76/75, 1975.
  • 2麦金太尔DA.室内气候[M].上海:上海科学技术出版社,1989.
  • 3Gan G,Ph D,Croome D J. Thermal comfort models based on field measurements, ASHRAE TRANSACTIONS, Vol. 100, partl, 1994.
  • 4Kwok Wai Horace Mui, Wai Tin Daniel Chan. Adaptive comfort temperature model of air-conditioned building building in Hong Kong[ J]. Building and Environment ,2003,38:837-852.
  • 5夏一哉,赵荣义,江亿.北京市住宅环境热舒适研究[J].暖通空调,1999,29(2):1-5. 被引量:158

同被引文献54

引证文献4

二级引证文献28

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部