摘要
In terms of the analogy between mass and heat transfer phenomena, a new physical quantity, i.e. mass entransy, is introduced to represent the ability of an object for transferring mass to outside. Meanwhile, the mass entransy dissipation occurs during mass transfer processes as an alternative to measure the mass transfer irreversibility. Then the concepts of mass entransy and its dissipation are used to develop the extremum principle of mass entransy dissipation and the corresponding method for convective mass transfer optimization, based on which an Euler's equation has been deduced as the optimization equation for the fluid flow to obtain the best convective mass transfer performance with some specific constraints. As an example, the ventilation process for removing gaseous pollutants in a space station cabin with a uniform air supply system has been optimized to reduce the energy consumption of the ventilation system and decrease the contaminant concentration in the cabin. By solving the op- timization equation, an optimal air velocity distribution with the best decontamination performance for a given viscous dissipation is firstly obtained. With the guide of this optimal velocity field, a suitable concentrated air supply system with appropriate air inlet position and width has been designed to replace the uniform air supply system, which leads to the averaged and the maximum contaminant concentrations in the cabin been decreased by 75% and 60%, respectively, and the contaminant concentration near the contaminant source surface been decreased by 50%, while the viscous dissipation been reduced by 30% simultaneously.
In terms of the analogy between mass and heat transfer phenomena, a new physical quantity, i.e. mass entransy, is introduced to represent the ability of an object for transferring mass to outside. Meanwhile, the mass entransy dissipation occurs during mass transfer processes as an alternative to measure the mass transfer irreversibility. Then the concepts of mass entransy and its dissipation are used to develop the extremum principle of mass entransy dissipation and the corresponding method for convective mass transfer optimization, based on which an Euler's equation has been deduced as the optimization equation for the fluid flow to obtain the best convective mass transfer performance with some specific constraints. As an example, the ventilation process for removing gaseous pollutants in a space station cabin with a uniform air supply system has been optimized to reduce the energy consumption of the ventilation system and decrease the contaminant concentration in the cabin. By solving the optimization equation, an optimal air velocity distribution with the best decontamination performance for a given viscous dissipation is firstly obtained. With the guide of this optimal velocity field, a suitable concentrated air supply system with appropriate air inlet position and width has been designed to replace the uniform air supply system, which leads to the averaged and the maximum contaminant concentrations in the cabin been decreased by 75% and 60%, respectively, and the contaminant concentration near the contaminant source surface been decreased by 50%, while the viscous dissipation been reduced by 30% simultaneously.
基金
Supported by the National Basic Research Program of China (Grant No. G2007CB206901)
关键词
极值原理
通风设计
空间站
净化
应用
耗散
convective mass transfer, mass entransy dissipation, space station, decontamination ventilation, optimization