摘要 目的:探讨锁定加压接骨板(LCP)在肱骨近端骨折中的应用效果。方法:采取切开复位内固定治疗肱骨近端骨折38例。结果:术后随访时间8-16个月(平均12个月),均获骨性愈合。采用N eer评分方法评定疗效,优良率89.5%。手术疗效显著。结论:肱骨近端骨折应用LCP治疗固定牢靠,可早期进行功能锻炼,肩关节功能恢复良好,应用效果良好。 Objective:To explore the clinical results of proximal humeral fractures treated with proximal humeral interlocking plates.Methods:Of all 38 patients with proximal humeral fractures,who received the treatment of interlocking plates.Results:Of 38 patients,all finished follow-up,all fractures healed successfully.To evaluate the postoperative function by Neer Scoring Criteria of shoulder joint function,the excellent rate was up to 89.5%.Conclusion:It is absolutely reliable to use the method of proximal humeral interlocking plates treating proximal humeral fractures with rare post operative complications.The clinical results are satisfied.
作者 卢斌
出处 《医药世界》 2009年第8期389-390,共2页 Medicine World
关键词 肩骨折/外科学 骨折固定术 骨板 人类 Shoulder Fractures/surgery Fracture Fixation Internal Bone Plates Humans
  • 相关文献

参考文献2

二级参考文献26

  • 1王满宜.骨折治疗的进展[J].创伤外科杂志,2004,6(6):401-403. 被引量:12
  • 2何发胜,苏青,蔡克冬.肱骨近端外侧钢板治疗肱骨外科颈骨折[J].中国骨与关节损伤杂志,2006,21(8):652-653. 被引量:9
  • 3McKoy BE, Bensen CV, Hartsock LA. Orthop Clin North Am, 2000,31(2) :205-216.
  • 4Ilchmann T,Ochsner PE,Wingstrand H, et aL Int Orthop, 1998; 22(5) :316-320.
  • 5Lill H , Josten C, Orthopade, 2000,29(4):327-341.
  • 6Lill H, Bewer A, Komer .J , et al Zentralbl Chir, 2001, 126(3):205-210.
  • 7Dawson FA. Arthroscopy, 2003; 19(6):662-666.
  • 8Herscovid D Jr, Saunders DT, Johnson MP, et al. CAin Orthop, 2000,375:97- 104.
  • 9Qidwai SA. J Trauma,2001 , 50(6) :1090-1095.
  • 10Wijgman AJ, Roolker W, Patt TW, et al. J Bone Joint Surg Am,2002; 84(11):1919-1925.

共引文献105

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部