摘要
通过对锅炉侧水冷壁和侧包覆等部位振动的实地测量以及刚性梁、侧水冷壁引出管的系统计算,详细分析了锅炉振动的原因,提出了防止振动的有效措施,取得了良好的效果。
Based on actual measurement on vibration at boiler side water wall and side enclosure wall, and systematic calculation on relevant buckstay and outlet pipe of boiler side water wall, causes of boiler vibration are being analyzed in detail, to which effective countermeasures have been proposed and taken, with good results obtained.
出处
《发电设备》
2009年第5期329-331,共3页
Power Equipment
关键词
锅炉
振动
引出管
刚性梁
改进
boiler vibration outlet pipe buckstay countermeasure