期刊文献+

交联聚乙烯电力电缆水树产生机理、检测及预防 被引量:25

Mechanism,Detection and Prevention of Water Treeing in XLPE Power Cables
下载PDF
导出
摘要 分析交联聚乙烯电力电缆绝缘中水树产生的机理及检测方法,并对如何防止绝缘中水树产生提出了解决措施。 In this paper the mechanism and detection of water treeing in the XLPE cable insulation were analyzed Measures to prevent water treeing generation in the cable insulation were recommended.
出处 《电线电缆》 2009年第4期1-3,7,共4页 Wire & Cable
关键词 交联聚乙烯电力电缆 水树 产生机理 预防 XLPE power cable water treeing mechanism of generation prevention
  • 相关文献

参考文献1

二级参考文献8

  • 1中出雅彦 (火田)中正树 国井久美子 等.酸化劣化に着目したCVク一ブルの寿命推定[J].电气学会论文(言志),2002,122(1):90-95.
  • 2内田克己.水卜リ一劣化CVク一ブルの余故里命诊断法[J].电气现场技术,1999,38(6).
  • 3ROSS R. Dealing with interface problems in polymer cable terminations [J]. IEEE Electrical Insulation Magmdne, 1999, 15 (4):5-9.
  • 4DENSLEY John. Ageing mechanisms and diagnostics for power cables-an overview [J]. IEEE Electrical Insulation Magszine,2001, 17(1): 14-22.
  • 5TIAN Y, LEWIN P L, DAVIES A E, et al. Comparison of on-line partial discharge detection methods for HV cable joints [J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2002, 9(4): 604-605.
  • 6BANKS V A A, NOYES R P, VAIL J, etal. Long term wet ageing of extruded dielectric cables [J]. Power Eagineeriag Journal ,2000, 14(6): 121-126.
  • 7NAGAMANI H N, CHANNAKESHAVA, Investigations on the failure modes of XLPE cables and joints [J]. IEEE Transactions on Power Delivery, 1998, 13(3): 706-711.
  • 8KATZ C, ZENGER W. Service aged 69 and 115 kV XLPE cables[J]. IEEE Transactions on Power Delivery, 1999, 14 (3):685-689.