期刊文献+

混凝土气泡特征参数测试方法研究 被引量:4

Research on the Air-void System Test Method against Air-entrained Concrete
下载PDF
导出
摘要 采用的ASTM C457(人工显微镜法)测试混凝土气泡特征参数的方法耗时耗力,且可重复性差,误差大。为了准确方便地测试混凝土的气泡特征参数,提高混凝土引气质量的鉴别效率,文章详细分析论述了数字图像分析、AVA测试仪和Rapid Air测试仪三种典型的先进气泡参数测试原理和过程,指出了三种方法与ASTM C457有很好的相关性,说明采用图像分析、AVA和Rapid Air分析混凝土气泡特征参数方便、准确和可信,具有一定应用价值。 Traditional test method of air void system by ASTM CA57 is too complicated, so three new excellent automatic test methods of air void system including AVA, Rapid Air and image analysis system are introduced and analyzed in detail in this paper. Their test results are consisted with the ASTM CA57, and it is more conve- nient and accurate to test the air void system with the instruments of AVA, Rapid Air and by the image analysis system. These methods shall be made more widespread for the measurement of the air void system.
出处 《红水河》 2009年第4期50-53,共4页 Hongshui River
基金 国家自然科学基金863项目(60672166 2009AA03Z508)
关键词 混凝土 气泡参数 测试方法 concrete air void system test method
  • 相关文献

参考文献12

  • 1Gao Peiwei, LU Xiaolin. Microstructure and pore structure of concrete mixed with superfine phosphorous slag and superplasticizer [J ]. Construction and Building Materials, 2008, 22: 837-840.
  • 2Michel, Pigenon, Jacques Marchand and Richard Pleau, Frost Resistant Concrete[J], Construction and Building Materials, 1996, 10(5): 339-348.
  • 3ASTM CA57, Standard test method for microscopical determination of parameters of air- void system in hardened concrete[S].
  • 4高培伟,吴胜兴,邓敏,林萍华,吴中如,唐明述.掺膨胀剂后碾压混凝土的抗冻特性研究[J].河海大学学报(自然科学版),2005,33(2):186-189. 被引量:7
  • 5B. W. Langan, M. A. Ward. Detennination of the Air - Void System Parameters in Hardened Concrete - An Error Analysis [J]. ACI. 1986, 11: 943-949.
  • 6Gao Peiwei. Shrinkage and expansive strain of concrete with fly ash and expansive agent. Journal of Wuhan University of Technology Materials Science, 2009, 24 (1) : 150 - 153.
  • 7汤国华,杨俊和,张琢,郑金标.一种定量分析多孔材料孔隙结构的新方法[J].煤炭转化,2004,27(1):71-75. 被引量:16
  • 8Jeremy Carlson. Advancement on the Application of a Flat- Bed Scanner for Hardened Portland Cement Concrete Air Void Analysis. Michigan Technological University. 2005.
  • 9Gene K. Fong, Gary Hoffman, Tony Sussmama. Championing innovations: roundabouts and ITS technologies in work zones are just two of the state- of- art technologies that FHWA and AASHTO encourage State and local agencies to adopt. Public Roads. 2004, 1: 4.
  • 10U.H. Jakobsen, C. Pade, N. Thaulow, D. Brown, S. Sahu. Automated air void analysis of hardened concrete[J] . Cement and Concrete Research. 2006, 36: 1444 - 1452.

二级参考文献22