氢气作为新型能源,已被运用于汽车领域,而作为燃料电池汽车发展的基础配套设施,加氢站有着举足轻重的地位。文章阐述了上海第一座汽车加氢站——安亭加氢站在其设计过程中遇到的防雷、防静电及接地的相关问题,提出了在爆炸危险环境中,建筑与工艺设备的防雷、防静电要求,和整个加氢站区内采用的接地形式,以及采取的相应解决方案。可供今后加氢站的相关设计提供借鉴。
The hydrogen is new model sources of energy and is used to automobile field. The hydrogen refueling station which is used for basis supporting facilities about the fuel cell automobile development has decisive position. The paper expatiates on the first Shanghai automobiles hydrogen refueling station ——An Ting hydrogen refueling station relevance problems about lightning protection, electrostatic prevention and earth connection in the process of its design. In explosion hazard environment, those buildings and technology equipments lightning-proof and anti-static need, earth connection style, and corresponding solutions scheme are put forwards to provide reference for hydrogen refueling station design in the future.
出处
《上海煤气》
2009年第4期21-23,26,共4页
Shanghai Gas
关键词
加氢站
爆炸危险环境
防雷
防静电
接地
hydrogen refueling station, explosion hazard environment, lightning protection, electrostatic prevention