摘要 用双灵敏度VISAR测试系统测量爆炸箔冲击片飞片速度,在测试大的金属飞片(直径大于1mm)速度的基础上,对小尺寸的镀铝聚酰亚胺飞片进行测试。通过三坐标激光调节仪对入射光和反射光的对中调试,使得反射光垂直于飞片平面并增加了反射光的强度;通过使用光电信号同步机及处理软件,得到了飞片的飞行速度。将VISAR测试结果与电磁测速法和格尼能公式计算结果进行对比,得到了较好的吻合。 A double sensitivity VISAR system was used to measure the flyer velocity of exploding foil initiator.Based on the measurement technology of veloctiy of big metal flyer, the small flyer velocity of kapton flyer plated with aluminum was also measured. By three coordinates adjusting device, the input and output laser could be focused on the flyer, and the intensity of output laser was enhanced. The flyer veloctiy was obtained by using the synchronization of light and electricity and software. The measurement results of VISAR was coincided well with the results of the electromagnetism measurement and Gumey energy formula.
机构地区 中国兵器工业第
出处 《火工品》 CAS CSCD 北大核心 2009年第2期42-44,共3页 Initiators & Pyrotechnics
关键词 爆炸箔起爆器 爆炸箔冲击片 飞片速度 VISAR测试系统 EFI Exploding foil initiator: Exploding foil slapper Flyer velocity VISAR test system EFI
  • 相关文献

参考文献6

二级参考文献29

  • 1李泽仁,李幼平,马如超,谭显祥.光纤传输速度干涉仪[J].爆炸与冲击,1994,14(2):175-181. 被引量:7
  • 2何碧,蒋小华,李泽仁,彭其先,何松伟,刘乔,邓向阳,龙新平,冯长根.用双灵敏度VISAR测试爆炸箔起爆器的飞片速度[J].爆炸与冲击,2005,25(1):31-34. 被引量:13
  • 3耿春余.电爆炸箔加速塑料片速度分析[J].含能材料,1995,3(2):37-43. 被引量:16
  • 4Shwarz A C. A new technique for determining the shock initiation sensitivity of explosives [R]. SAND77-0416C, 1977.
  • 5Cutting J L, Lee R S, Hodgin R L. Quantic Industries Inc. Slapper detonator PerformAnce[R]. UCRL-ID-117787, 1994.
  • 6Tucker T J, Stanton P L. Electrical Gurney energy: a new concept in modeling of energy transfer from electrically exploded conductors[R]. SAND75-0244, 1975.
  • 7Schwarz A C. Study of factors wich influence the shock-initiationsensitivity of hexanitrostilbene(HNS) [ R] , SAND80-2372, 1980.
  • 8Rhoton N O. Flyer sensitivity test[R]. MHSMP81-09, 1981.1.
  • 9Meyer T O. Velocity perturbation of a flyer approaching a rigid impermeable barrier and the transmitted pressure pulse[R]. 83007770.
  • 10Paisley D L, Montoya N, Stahl D B, et al. Interfometer and high speed photography of laser-driven flyer plate[R].89016990.

共引文献43

同被引文献21

  • 1何碧,蒋小华,李泽仁,彭其先,何松伟,刘乔,邓向阳,龙新平,冯长根.用双灵敏度VISAR测试爆炸箔起爆器的飞片速度[J].爆炸与冲击,2005,25(1):31-34. 被引量:13
  • 2邓向阳,彭其先,赵剑衡,王珪吉,刘俊,谭福利,唐晓松.VISAR测量电爆炸箔驱动飞片速度的实验研究[J].火炸药学报,2007,30(2):45-48. 被引量:8
  • 3耿春余.一种简易测量小飞片速度的方法.科技学报,1984,(1):34-37.
  • 4PrinseWC, Van't Hof P G, Cheng L K, et al. High-speed re-Iocity measurements on an EFI-system [ C ] //27th International congress on High-Speed Photography and Photonics. Internation- al Society for Optics and Photonics, 2007 : 62795E-62795E-10.
  • 5Davies H R, Chapman D J, Vine T A, et al. Characterization of an exploding foil initiator (EFI) system [ C]//Proceedings of the American Physical Society Topical Group on Shock Compression of Condensed Matter, AlP Publishing, 2009,1195(1): 283- 286.
  • 6Hodgin R, May C, Hanks R, et al. Fabry-Perot/PDV Compari, son[R]. UCRL-CONF-230794. 2007.
  • 7Hatt D J. A VlSAR velocity interferometer system at MRL for slap- per detonator and shockwave studies [ R ]. MRL-TR-91-42. 1991.
  • 8Strand O T, Berzins L V, Goosman D R, et al. Velocimetry using heterodyne techniques[ C]//26th International Congress on High-Speed Photography and Photonics. Alexandria, VA, 2004: 593 -599.
  • 9Lowry M E, Molau N E, Sargis P D, et al. Photonic doppler velocimetry[ R]. UCRL-ID-133075. 1999.
  • 10Dolan D H. Accuracy and precision in photonic Doppler veloci- metry [ J ]. Review of Scientific Instruments, 201 0, 81 ( 5 ) : 3905 -3907.

引证文献2

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部