期刊文献+

660MW机组低压加热器停运后高压加热器预防措施

Hazard to High-pressure Feed Water Heater by Low-pressure Feed Water Heater Outaging and Preventive Action in 660MW Unit
下载PDF
导出
摘要 分析了邯峰发电厂高压加热器泄漏的典型案例,阐述了低压加热器停运后对高压加热器的影响。按照绝大多数电厂的抽汽加热布置方式,提出了利用辅汽提高高压加热器入口水温的解决方案。 The leakage damages of No. 6 high-pressure feed water heater in Hanfeng Power Plant were analyzed. It showed the hazard to the high-pressure feed water heater by the low-pressure feed water heater outaging. Solutions were proposed to increase feed water temperature with auxiliary steam in majority power plants layout.
出处 《电力科学与工程》 2009年第8期52-54,共3页 Electric Power Science and Engineering
关键词 高压加热器 除氧器 低压加热器 泄漏 high-pressure feed water deoxygenator low-pressure feed water heater leakage