摘要
分析了邯峰发电厂高压加热器泄漏的典型案例,阐述了低压加热器停运后对高压加热器的影响。按照绝大多数电厂的抽汽加热布置方式,提出了利用辅汽提高高压加热器入口水温的解决方案。
The leakage damages of No. 6 high-pressure feed water heater in Hanfeng Power Plant were analyzed. It showed the hazard to the high-pressure feed water heater by the low-pressure feed water heater outaging. Solutions were proposed to increase feed water temperature with auxiliary steam in majority power plants layout.
出处
《电力科学与工程》
2009年第8期52-54,共3页
Electric Power Science and Engineering
关键词
高压加热器
除氧器
低压加热器
泄漏
high-pressure feed water
deoxygenator
low-pressure feed water heater
leakage