根据黑启动的一般准则和株洲电网实际情况,制定了株洲电网的黑启动方案,并就大型辅机启动时对小系统的冲击及带负荷时对系统频率的影响进行详细的仿真研究,校验了方案的可行性,为今后的现场试验和方案的实施提供依据和建议。
According to general criterion of black - start and practical situation of Zhuzhou power grid, the black - start scheme for Zhuzhou power grid was established. The impact of large asynchronous motor startup on small power grid and the influence of pickup load on system frequency were thoroughly simulated and studied. The feasibility of scheme was verified by simulating calculation, offering references and suggestions for the future field test and scheme implementation.