光谱发射率测量技术 被引量:30

Review of spectral emissivity measurement
下载PDF
导出
摘要 论述了光谱发射率在航天、航空、国防、军事及国民经济各领域中的实际应用和重要意义。材料光谱发射率的影响因素很多,且应用背景差异较大,各国分别建立了各具特色的发射率测量装置。根据测量特点及应用范围,发射率测量方法分4大类:量热法、反射法、能量法和多波长法。针对每种测量方法介绍了基本原理、装置特点、技术指标和发展现状。简单介绍了基于红外傅里叶分析光谱仪建立的光谱发射率测量系统,进而描述了材料发射率在重要领域的具体应用情况。分析了我国目前在发射率测量技术方面存在的问题,展望了我国发射率测量技术的发展趋势和发射率数据库方面的进一步工作。 The practical application and vital significance of spectral emissivity in astronautics, aeronautics, national defense and military have been discussed. Since there are many influence factors on spectral emissivity and its application, a lot of emissivity measurement apparatus in different types have been set up in many countries. According to the measurement characteristic and application scope, the emissivity measurement methods were classified as four kinds, calorimetric, reflection, energy and multi-wavelength method. The basic schematic, apparatus characteristic, technique index and development status were introduced for every method. The emissivity measurement apparatus based on infrared Fourier analysis spectrometer were introduced. The specific applications in the vital fields were described. And the problems existed in our country for the emissivity measurement have been analyzed. Finally, the tendency and future work on data base of the emissivity measurement were forecasted.
出处 《红外与激光工程》 EI CSCD 北大核心 2009年第4期710-715,共6页 Infrared and Laser Engineering
关键词 计量学 发射率测量 综述 辐射 温度 Metrology Emissivity measurement Review Radiation Temperature
  • 相关文献

参考文献16

  • 1CHU Zai-xiang,SUN Yu-xing, CHEN Shou-ren. Material spectra emissivity measurement technique[J].Infrared Research ,1986, 5A:231-239.
  • 2CEZAIRLIYAN A,MCCLURE J,LAYLOR R. Thermophysical measurements on 90Ti-6Al-4V alloy above 1 450 K using a transinent technique [J].Journal of Research of the National Bureau of Standards, Section A, Physics and Chemistry, 1977,81 (3): 251-256.
  • 3RIGHINI F, ROBERTS R B, ROSSO A.Measutrment of thermophysical properties by a pulse-heating method: niobium in the range 1 000-2 500 K[J].International Journal of Thermophysics, 1985,6 (6): 681-693.
  • 4KASCHNITZ E, POTTLACHER G,JAEGER H. New microsecond pulse-heating system to investigate thermophysical properties of solid and liquid metals[J].International Journal of Thermophysies, 1992,13 (4): 699.
  • 5DAI J M, FAN Y, CHU Z X.Development of a Millisecond Pulse-Heating Apparatus[J].International Journal of Thermophysies, 2002,23 ( 5 ): 1401 - 1405.
  • 6DUNKLE R V. In Progress in International Research on Thermodynamics and Transport Properties Asme[M].1962: 100-106.
  • 7LIU Baoming, CHU Zaixiang.Effect of deviation of cavity temperature and wal! emissivity on accuracy of material emissivity measurement [C]//10th European conference on Thermophysical Properties, 1986:22-26.
  • 8ISHII J, ONO A.Uncertainty estimation for emissivity measurements near room temperature with a Fourier transforms spectrometer[J].Meas Sci Technol,2001,12:2103-2112.
  • 9LINDERMEIR E, TANK V, HASCHBERGER P.Contactless Measurement of the spectral emissivity and tempe- rature of surfaces with a fourier transform infrared spectrometer [C]// Proceedings of SPIE, Thermosense XIV: An Intl Conf on Thermal Sensing and Imaging Diagnostic Applications ,1992, 1682: 354 -364.
  • 10MARKHAM J R, KINSELLA K, CARANGELO R M,et al.A bench top FT -IR based instrument for simultaneously measuring surface spectral emittance and temperature [J].Rev Sci Instrum, 1993,64(9) :2515-2522.

同被引文献197

引证文献30

二级引证文献88

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部