摘要 A method was developed to restore degraded images to some extent after the pixel binning pro- cess in image sensors to improve the resolution. A pixel binning model was used to approximate the original un-binned image. Then, the least squares error criterion was used as a constraint to reconstruct the re- stored pixel values from the binning model. The technique achieves about a one-decibel increase in the peak signal-to-noise ratio compared with the original estimated image. The technique has good detail pre- servation performance as well as low computation load. Thus, this restoration technique provides valuable improvements in practical, real time image processing. A method was developed to restore degraded images to some extent after the pixel binning pro- cess in image sensors to improve the resolution. A pixel binning model was used to approximate the original un-binned image. Then, the least squares error criterion was used as a constraint to reconstruct the re- stored pixel values from the binning model. The technique achieves about a one-decibel increase in the peak signal-to-noise ratio compared with the original estimated image. The technique has good detail pre- servation performance as well as low computation load. Thus, this restoration technique provides valuable improvements in practical, real time image processing.
出处 《Tsinghua Science and Technology》 SCIE EI CAS 2009年第4期541-545,共5页 清华大学学报(自然科学版(英文版)
基金 Supported by the National Key Basic Research and Development(973) Program of China (No. 2006CB705700)
关键词 image restoration image sensors pixel binning image restoration image sensors pixel binning
  • 相关文献

参考文献10

  • 1Yang G,Dosluoglu T.A column averaging/row binning circuit for image sensor resolution adjustment in lower in- tensity light environment[].European Patent.2006
  • 2Guidash R.CMOS image sensor pixel with selectable binning[].WO Patent WO/ /.2006
  • 3Srinivas Y,Wilson D L.Quantitative image quality evalua- tion of pixel-binning in a flat-panel detector for X-ray fluo- roscopy[].Medical Physics.2004
  • 4Matsuura N,Zhao W,Huang Z,Rowlands J A.Digital radiology using active matrix readout: Amplified pixel detector array for fluoroscopy[].Medical Physics.1999
  • 5Jardin W D,Parks C,Doan H,Kurfiss N,Wetzel K.A large format, high-performance CCD sensor for medical X-ray applications[].Proceedings of SPIE: Medical Imaging.2000
  • 6Bock N E.Apparatus and method for pixel binning in an image sensor[].US Patent B.2006
  • 7Yang G,Dosluoglu T.An image sensor having resolution adjustment employing an analog column averaging/row averaging for high intensity light or row binning for low intensity light[].European Patent.2006
  • 8Guidash R M.Image sensor with charge binning[].European Patent.2006
  • 9Zhimin Zhou,Bedabrata Pain,Eric R.Fossum.Frame-Transfer CMOS active pixel sensor with pixel binning[].IEEE Transactions on Electron Devices.1997
  • 10Til Aach,,Ulrich Schiebel,and Gerhard Spekowius.Digital image acquisition and processing in medical x-ray imaging[].Journal of Electronic Imaging.1999

同被引文献9

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部