期刊文献+

Safety,Tolerability and Pharmacokinetic Study of Recombinant Human Parathyroid Hormone [rhPTH(1-84)] in Chinese Healthy Volunteers 被引量:3

Safety,Tolerability and Pharmacokinetic Study of Recombinant Human Parathyroid Hormone [rhPTH(1-84)] in Chinese Healthy Volunteers
下载PDF
导出
摘要 The current study was designed to determine the safety, tolerability and pharmacokinetic parameters of recombinant human parathyroid hormone [rhPTH (1-84)] used for the treatment of osteoporosis. In the single-dose format pharmacokinetic study, thirty-six healthy male volunteers received three dose levels of rhPTH (1-84) subcutaneously: 1, 2, and 4 μg/kg. The blood was timing drawn and the serum concentration of rhPTH (1-84) was determined by enzyme linked immunosorbent assay (ELISA). Serum concentration-time curves of PTH (1-84) exhibited a double-peak pattern, the first peak appearing about 10 to 30 min after administration and the second peak occurring about 1.5 to2 h after administration. Serum terminal half-time of PTH (1-84) was approximately 2 h. The parameters indicated the serum levels were directly proportional to the administered dose, with the mean Cmax and AUC0_24 ranging from approximately 543.47 to 1845 pg/mL and 2358.6 to 9232.12 pg.h.mL^-1 over the dose range. The drug was well tolerated, the clinical symptoms were generally mild and of short duration. The current study was designed to determine the safety, tolerability and pharmacokinetic parameters of recombinant human parathyroid hormone [rhPTH (1-84)] used for the treatment of osteoporosis. In the single-dose format pharmacokinetic study, thirty-six healthy male volunteers received three dose levels of rhPTH (1-84) subcutaneously: 1, 2, and 4 μg/kg. The blood was timing drawn and the serum concentration of rhPTH (1-84) was determined by enzyme linked immunosorbent assay (ELISA). Serum concentration-time curves of PTH (1-84) exhibited a double-peak pattern, the first peak appearing about 10 to 30 min after administration and the second peak occurring about 1.5 to2 h after administration. Serum terminal half-time of PTH (1-84) was approximately 2 h. The parameters indicated the serum levels were directly proportional to the administered dose, with the mean Cmax and AUC0_24 ranging from approximately 543.47 to 1845 pg/mL and 2358.6 to 9232.12 pg.h.mL^-1 over the dose range. The drug was well tolerated, the clinical symptoms were generally mild and of short duration.
出处 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2009年第4期431-434,共4页 华中科技大学学报(医学英德文版)
关键词 SAFETY TOLERABILITY pharmacokineties recombinant human parathyroid hormones safety tolerability pharmacokineties recombinant human parathyroid hormones
  • 相关文献

参考文献4

二级参考文献25

共引文献16

同被引文献17

引证文献3

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部