摘要
通过对循环水场的10台进口凉水塔风机近年来不断出现的设备问题进行调查统计,分析了各种故障产生的原因,并提出了提高风机运行可靠性的措施。
Reasons for variors troubles caused are analysed through the investigation of equipment problems often appeared in recent year for ten cooling tower fan on the circulating water field,and the measures for increasing fan operating reliability are raised .
出处
《风机技术》
北大核心
1998年第4期38-40,共3页
Chinese Journal of Turbomachinery
关键词
凉水塔风机
故障分析
可靠性
Cooling Tower Fan Trouble Analysis Reliability