期刊文献+

锆钢复合板设备检漏结构改进及检验方法实践 被引量:1

Improvement of Leak Detection Structure of Zirconium Titanium Steel Clad Equipment and Its Testing Method
下载PDF
导出
摘要 设计合理的检漏结构和检验方法,是保证醋酸和醋酐装置中关键复合板设备质量要求最行之有效的方式之一。本文以锆钢复合板设备为实践基础,从复合板的物理性能、设备使用工况和制造工艺出发,对复合板设备原有的检漏结构进行了改进,通过合理的检验方法对设备复层焊缝进行密封性检验,保证了设备的安全性和可靠性。 Designing reasonable leak detection structure and testing method is one of the most effective way to ensure quality of the clad plate critical equipment such as acetic acid and acetic anhydride. This paper, based on zirconium titanium steel clad equipment, the main physical properties of materials, equipment working conditions and manufacturing process, improves the original leak detection structure on the composite plate and carries out dense test of composite-seam through a reasonable testing method to ensure the safety and reliability of equipment.
出处 《中国特种设备安全》 2009年第8期41-43,共3页 China Special Equipment Safety
关键词 检漏结构 锆钢复合板 检验方法 Leak detection structure Zirconium titanium steel clad Testing method
  • 相关文献

参考文献3

  • 1黄嘉琥.压力容器材料使用手册一特种材料.北京:化学工业出版社.1997.
  • 2ASTM B898--99 Standard Specification for Reactive and Refractory Metal Clad Plate.1999.
  • 3王应植,袁彪,张林贤,郑杨艳.锆-钢复合板压力容器制造技术研究[J].石油机械,2008,36(6):28-30. 被引量:12

二级参考文献7

共引文献11

同被引文献5

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部