日产1.8吨小奶站采用热泵制冷供热系统的经济性分析

Economic analysis of heat pump refrigerating/heating system for milk station with production of 1.8 t/d
下载PDF
导出
摘要 为了保持牛奶新鲜,牛奶收集站须先将牛奶降到4~6℃,再运送或保存。本文提出奶站采用热泵给牛奶降温的同时将水加热以供清洗之用,并从初投资和年运行费用2方面,对这种新的制冷供热方式与传统制冷供热系统进行比较。结果表明,奶站采用热泵制冷供热系统的年运行费用是风冷式制冷奶罐与燃煤锅炉系统的66.2%,是风冷式制冷奶罐与太阳能系统的65%,预计4.1年可收回其初投资费用,而且热泵制冷供热清洁,不污染环境。 In order to maintain fresh milk, milk collection station need to make the milk's temperature drop to 4-6 ℃ to delivery or preservation. Proposes using the heat pump to drop the milk's temperature at the same time increase the water's temperature for cleaning. From the initial investment and annual running costs, compares the new refrigerating/heating system with traditional system. The result shows that the annual run- ning cost of heat pump refrigerating/heating system is 66.2% of the air cooling tank & boiler system and 65% of the air cooling tank & solar energy system, estimates that the initial investment will be taken back in 4. 1 years. Furthermore this system is no pollution to the environment
机构地区 内蒙古工业大学
出处 《制冷与空调》 2009年第4期76-79,共4页 Refrigeration and Air-Conditioning
关键词 制冷 供热 热泵 经济性分析 节能 refrigeration heating heat pump economic analysis energy-saving
  • 相关文献

参考文献7

  • 1图森斯基.太阳能在小型牛奶收集和加工系统中的应用.北京:中国农业科技出版社,1987:33-50.
  • 2June Roberts, George H. Milk cooling on Kansas Farms. Kansas Bulletin No. 295,1941:8-22.
  • 3吕灿仁.热泵及其在我国的应用的前途[J].动力机械,1957,(2):13-19.
  • 4R G Winfield. Heat Recovery From Milk Cooling Systems. Ministry of Agriculture Food and Rural Affairs, 1996 (519) : 826-947.
  • 5H Helikson, R Bucklin, D Bray, et al. Energy Efficiency on the Florida Dairy. University of Florida Fact Sheet EES-74,1991 : 1-4.
  • 6包涛,董玉军,周翔,胡跃明,袁秀玲,郭凯.热泵系统的经济性分析[J].制冷,2004,23(2):83-86. 被引量:11
  • 7龚延风.空气源热泵全年运行的经济性分析[J].流体机械,2002,30(3):58-62. 被引量:8

二级参考文献9

  • 1Mcihele VID.关于空气源热泵机组的COP值[J].暖通空调技术.上海市暖通情服网,1998,.
  • 2Gregory Rosenquist and Peter Chan, Alex Lekov, Consumer Life-Circle cost Impacts of Energy - Efficiency Standards for Residential-Type Central Air Conditioner and Heat Pump [J]. Ernest Orlando Lawrence Berkeley National Laboratory
  • 3Douglas Cane, Andraw M orrison, Christopher J Ireland. Operating Experience With Commercial Ground Source Heat Pump [J]. ASHRAE Transactions, 1998, Part2: 677-687
  • 4K. Kaygusuz and T. Ayhan, Experimental and theoretical investigation of combined solar heat pump system for residential heating[J]. Energy conversion & managent, 40( 1999): 1377-1396
  • 5解鲁生.能源基础管理与经济[M].北京:冶金工业出版社,1991,10..
  • 6H基恩 A 哈登费尔特.电动热泵的应用[M].北京:机械工业出版社,1987..
  • 7胡欣,龙惟定,马九贤.CEC——一种有效的空调系统能耗评价方法[J].暖通空调,1999,29(3):16-18. 被引量:21
  • 8王勇,付祥钊,曾淼,胡鸣明,刘宪英.地源热泵地下管群换热器设计施工问题[J].建筑热能通风空调,2000,19(1):59-62. 被引量:9
  • 9龚延风.空气源热泵全年运行的经济性分析[J].流体机械,2002,30(3):58-62. 被引量:8

共引文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部